{"id":43416152866906,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"100-E190E","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 100-E190E IEC Contactor","public_title":null,"options":["Default Title"],"price":12300,"weight":2000,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 100-E190E IEC Contactor

Configured for high-current motor switching and power circuit interruption in Allen-Bradley motor control assemblies, the Allen-Bradley 100-E190E (100-E190E IEC contactor) provides direct electrical execution through electronically controlled AC/DC coil operation and three-pole load switching architecture.

Hardware Specifications

Parameter Specification
Model 100-E190E
Brand Allen-Bradley
Product Series Bulletin 100-E
Product Type IEC contactor
Origin Not specified in supplied documentation
Pole Configuration 3-pole
Auxiliary Contacts 1 NO + 1 NC
Coil Type Electronic wide-range AC/DC
Coil Voltage Range 100...250 V AC/DC
Rated Operational Current AC-3 190 A at 415 V
Rated Operational Current AC-1 275 A at 690 V
Rated Operational Current AC-3 at 1 kV 85 A
Motor Power Rating 90 kW at 415 V
Motor Power Rating 132 kW at 690 V
Motor Power Rating AC-3 at 1 kV 110 kW
Insulation Voltage 1000 V
Frequency 50/60 Hz
Surge Suppression Integrated
Certifications IECEx, CE, UL
Lifecycle Status Active
Dimensions Not specified in supplied documentation
Weight Not specified in supplied documentation
Operating Temp 60 deg C maximum reference for AC-3 current rating
Power Consumption Low coil power consumption design; exact value not specified

Firmware and Coil Control Compatibility

The 100-E190E utilizes an electronic wide-range AC/DC coil structure intended to simplify control voltage integration across industrial automation panels. Internal electronic regulation permits operation from 100...250 V AC/DC without mechanical coil replacement.

Integrated surge suppression circuitry reduces transient propagation generated during contactor coil de-energization. This arrangement minimizes conducted voltage disturbances entering adjacent PLC I/O channels, relay interfaces, or distributed control circuits.

The contactor architecture supports integration into deterministic industrial control networks through standard auxiliary contact feedback circuits connected to PLC digital input monitoring systems.

Frequently Asked Questions

Q: Can the 100-E190E be installed inside enclosed motor control cabinets without forced cooling?
A: Cabinet thermal conditions must remain within the operating limits of the connected equipment. Additional ventilation may be required when the contactor operates continuously near maximum AC-3 current ratings.

Q: Does the electronic coil require polarity control on DC supply inputs?
A: The supplied documentation identifies the coil as a wide-range electronic AC/DC type. Installation wiring should follow terminal markings provided on the device label or manufacturer wiring diagram.

Q: Are auxiliary contacts mechanically linked to the main contact assembly?
A: The unit includes 1 NO and 1 NC auxiliary contacts intended for status feedback and interlock circuits associated with the main switching mechanism.


Field Installation Guidelines

Mount the contactor vertically on a rigid panel or approved mounting assembly with sufficient clearance for conductor bending radius and heat dissipation. Torque all power terminals according to manufacturer installation procedures to prevent thermal rise at high current loading.

Separate control wiring from high-current load conductors where possible. Coil control circuits and PLC feedback conductors should not be bundled in parallel with motor feeder cables over extended distances.

Verify phase balance and insulation integrity before energizing the contactor under load. When switching inductive motors or transformers, confirm coordination with upstream overload and short-circuit protective devices.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products