{"id":43417426722906,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"140-CMN-6300","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 140-CMN-6300 Motor Protection Circuit Breaker","public_title":null,"options":["Default Title"],"price":12300,"weight":1950,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 140-CMN-6300 Motor Protection Circuit Breaker

The Allen-Bradley 140-CMN-6300 serves as the primary 140-CMN-6300 Motor Protection Circuit Breaker utilized to execute thermal overload interruption and magnetic short-circuit isolation across Bulletin 140M motor branch protection platforms. The device combines manual motor switching capability with adjustable trip protection for three-phase feeder circuits operating between 230 VAC and 690 VAC.

Hardware Specifications

Parameter Specification
Model 140-CMN-6300
Brand Allen-Bradley
Product Type Motor Protection Circuit Breaker
Product Family Bulletin 140M Circuit Breakers Series
Weight 4.30 lbs
Dimensions Not specified in provided documentation
Operating Temp Not specified in provided documentation
Power Consumption Passive protective device
Rated Operational Current 63 A
Maximum Current 90 A
Trip Setting Range 40-63 A
Trip Class 10
Operating Voltage 230-690 VAC
Rated Frequency 40-60 Hz
Magnetic Release Current 890 A
Mechanical Operations 30,000 cycles
Electrical Operations 5,000 cycles
Switching Frequency 20 operations/hour
Wire Size #8-14 AWG copper wire
Torque Requirement 6-10 Nm
Short Circuit Protection Integrated magnetic trip
Standards Compliance IEC/EN60947-1, IEC/EN60947-2, UL508, CSA C22.2 No.14
Certifications CE, UL, CSA, cULus

Firmware Flash Compatibility and Motor Branch Integration

The Bulletin 140M series is designed for direct integration with Allen-Bradley motor starter assemblies and industrial branch protection architectures. Mechanical coordination between the MPCB and downstream contactors allows motor feeder isolation without external molded-case breaker assemblies in compact panel layouts.

Thermal trip adjustment from 40 A to 63 A permits coordination with varying motor full-load current conditions while maintaining consistent magnetic short-circuit interruption characteristics. The device supports installation within industrial motor control centers using standardized Allen-Bradley mounting and feeder connection arrangements.

Frequently Asked Questions

Q: Does the 140-CMN-6300 support hot replacement while energized?
A: The breaker is intended for de-energized installation and removal procedures. Mechanical replacement under live feeder conditions is not specified.

Q: What is the function of Trip Class 10 protection?
A: Trip Class 10 defines the thermal overload response timing for motor starting currents and overload conditions in accordance with IEC motor protection requirements.

Q: Can the breaker operate as both a disconnect and overload protection device?
A: Yes. The unit combines manual switching, thermal overload protection, and magnetic short-circuit interruption within a single enclosure.


Field Installation Guidelines

Verify conductor sizing before termination. Use only copper conductors within the specified #8-14 AWG range and apply terminal tightening torque between 6 Nm and 10 Nm.

Install the breaker in a vertical orientation unless alternate mounting positions are approved within the associated control enclosure documentation. Maintain clearance from high-temperature components to prevent thermal drift of overload trip characteristics.

Separate motor feeder conductors from low-voltage control wiring to reduce electromagnetic coupling during short-circuit interruption events. Confirm that upstream protective coordination matches the breaker interruption characteristics before energization.

After installation, perform manual mechanical operation checks and verify adjustable thermal trip settings against the motor full-load current rating prior to commissioning.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products