Skip to content
Allen-Bradley 140M-K8P-D40 Motor Protection Circuit Breaker

Allen-Bradley 140M-K8P-D40 Motor Protection Circuit Breaker

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 140M-K8P-D40

  • Condition: In stock

  • Product Type: Motor Protection Circuit Breaker

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 3992g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43417446219866,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"140M-K8P-D40","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 140M-K8P-D40 Motor Protection Circuit Breaker","public_title":null,"options":["Default Title"],"price":12300,"weight":3992,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 140M-K8P-D40 Motor Protection Circuit Breaker

Configured for adjustable magnetic motor branch protection in Bulletin 140M motor control systems, the Allen-Bradley 140M-K8P-D40 (140M-K8P Motor Protection Circuit Breaker) provides direct electrical interruption for high-current three-phase motor feeders with fixed thermal characteristics and magnetic-only trip execution.

Suffix Breakdown & Model Matrix

The provided documentation identifies the unit as a fixed catalog configuration within the Bulletin 140M series. No manufacturer-defined suffix matrix or configurable ordering breakdown was specified in the source material.

Hardware Specifications

Parameter Specification
Model 140M-K8P-D40
Brand Allen-Bradley
Origin Rockwell Automation
Product Type Motor Protection Circuit Breaker
Product Family Bulletin 140M
Frame Size K Frame
Pole Configuration 3 Pole
Rated Current 120 A
Trip Range 2000-4000 A magnetic trip
Protection Type Adjustable magnetic only
Operating Voltage 480 VAC
Frequency 60 Hz
Motor Rating 90 HP
Interrupt Rating High break
Rated Impulse Withstand Voltage 8 kV
Minimum Operating Temp -25 deg C
Maximum Operating Temp 70 deg C
Minimum Storage Temp -40 deg C
Maximum Storage Temp 80 deg C
Installation Altitude 1000 m
Mounting Type Panel mount
Weight 8.80 lbs
Dimensions Not specified
Power Consumption Passive protection device; no external control power required

EtherNet/IP and Backplane Integration Characteristics

The Bulletin 140M protection platform is commonly deployed alongside Allen-Bradley motor control assemblies interfaced through deterministic industrial networks including EtherNet/IP architectures. In coordinated motor control panels, the breaker trip state is typically monitored through auxiliary contact assemblies connected to Logix input structures for status acquisition and interlock handling.

The K-frame mechanical construction supports higher feeder density within MCC sections while maintaining clearance spacing for high magnetic trip thresholds. Firmware dependency is not applicable to the breaker itself because trip execution is electromechanical rather than processor-controlled.

Frequently Asked Questions

Q: Does the 140M-K8P-D40 support hot replacement while the motor feeder remains energized?
A: Mechanical replacement should only be performed after upstream isolation and lockout procedures are completed. The breaker is not specified for energized insertion or removal.

Q: Is external control power required for trip operation?
A: No. Magnetic trip execution operates independently from auxiliary control voltage sources. Protective interruption is performed internally by the breaker mechanism.

Q: Can the breaker be mounted directly beside other high-current devices in a control enclosure?
A: Side-by-side mounting depends on enclosure thermal conditions and manufacturer spacing practices. Heat dissipation and conductor bending radius must be verified during panel layout.


Field Installation Guidelines

  • Verify conductor torque against terminal labeling before energization.

  • Separate motor power conductors from low-level analog or communication wiring inside the enclosure.

  • Use copper conductors within the specified terminal wire range and insulation rating.

  • Confirm short-circuit coordination with upstream protective devices before commissioning.

  • Maintain enclosure grounding continuity between panel backplate, breaker mounting structure, and incoming feeder ground.

  • Perform insulation resistance testing on feeder conductors before connecting the motor branch circuit to the breaker terminals.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products