Skip to content
Allen-Bradley 1440-ACNR ControlNet Communication Adapter

Allen-Bradley 1440-ACNR ControlNet Communication Adapter

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1440-ACNR

  • Condition: In stock

  • Product Type: ControlNet Communication Adapter

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43421579706458,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1440-ACNR","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1440-ACNR ControlNet Communication Adapter","public_title":null,"options":["Default Title"],"price":12300,"weight":500,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1440-ACNR ControlNet Communication Adapter

The Allen-Bradley 1440-ACNR serves as the primary 1440-ACNR ControlNet communication adapter utilized to execute XM module data exchange across ControlNet industrial automation platforms.

Hardware Specifications

Parameter Specification
Model 1440-ACNR
Brand Allen-Bradley
Manufacturer Rockwell Automation
Product Series XM Series
Product Type ControlNet Communication Adapter
Controller Compatibility ControlLogix, MicroLogix 1500
Network Protocol ControlNet
Module Type Analog I/O and ControlNet Adapter
Analog Channels 8
Signal Types Voltage and current
Resolution 16-bit
Accuracy +/- 0.25 %
Power Supply 24 V Class 2
Indicators 4 status LEDs
Protection Rating IP20
Operating Temp -40 deg C to 70 deg C
Dimensions 152 mm x 89 mm x 25 mm
Shipping Dimensions 210 mm x 50 mm x 280 mm
Weight 0.5 kg
Power Consumption Not specified in supplied documentation

Deterministic ControlNet Communication Architecture

The 1440-ACNR adapter transfers XM module process data through scheduled ControlNet communication cycles. Deterministic network timing permits synchronized analogue data acquisition between XM monitoring modules and ControlLogix or MicroLogix controllers.

The adapter supports multi-channel analogue signal transport with 16-bit conversion handling. Signal scaling and filtering functions are executed through XM configuration parameters and ControlNet network mapping structures.

ControlNet network continuity requires proper coaxial segment termination and validated node addressing before controller synchronization. LED indicators provide local diagnostics for adapter status, backplane communication state, and network activity conditions.

Frequently Asked Questions

Q: Does the 1440-ACNR require external network termination hardware?
A: Yes. ControlNet segment installation requires approved termination resistors at both ends of the network trunk to maintain communication stability.

Q: Can the module operate without an external enclosure?
A: The adapter carries an IP20 protection rating and should be installed inside an industrial control enclosure for protection against conductive dust and moisture exposure.

Q: Is firmware compatibility important between the adapter and XM modules?
A: Yes. Firmware revision compatibility between the 1440-ACNR adapter, XM modules, and host controllers should be verified before commissioning or firmware replacement procedures.


Field Installation Guidelines

Install the adapter within a grounded control cabinet using vibration-stable mounting hardware. Maintain separation between ControlNet communication cabling and high-current motor conductors to reduce electromagnetic coupling into network segments.

Use approved ControlNet coaxial cable and validated termination resistors during network assembly. Avoid sharp cable bends and maintain continuous shield grounding according to Rockwell Automation network installation practice.

Verify 24 V Class 2 supply polarity before energizing the adapter. Inspect LED diagnostic states during startup to confirm backplane communication and ControlNet token exchange status.

Do not install the module directly in environments exposed to oil mist, conductive dust, or water ingress without secondary enclosure protection. Maintain enclosure ventilation clearance to reduce thermal accumulation around communication circuitry.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products