{"product_id":"allen-bradley-1440-spd02-01rb-xm-220-speed-measurement-module","title":"Allen-Bradley 1440-SPD02-01RB XM-220 Speed Measurement Module","description":"\u003ch1\u003eAllen-Bradley 1440-SPD02-01RB XM-220 Speed Measurement Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1440-SPD02-01RB\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1440-SPD02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpeed Measurement Module, operates as a dedicated hardware component for shaft speed, acceleration, and overspeed monitoring within XM condition monitoring networks. The module processes two tachometer input channels and transmits analog output signals for machine protection and rotational speed supervision.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1440-SPD02-01RB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eXM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSpeed Measurement Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eXM-220 Dual Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTachometer Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 analog outputs, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e0.0167 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eTerminal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Function\u003c\/td\u003e\n\u003ctd\u003eSpeed, acceleration, and overspeed measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeviceNet Integration and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1440-SPD02-01RB exchanges rotational speed data through XM platform communication structures and supports integration with distributed monitoring architectures. Module operation depends on correct firmware revision matching between the speed measurement module and associated XM communication adapters. Backplane communication timing and parameter synchronization should be verified during commissioning when multiple measurement modules operate within the same enclosure assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1440-SPD02-01RB accept direct tachometer sensor wiring?\u003cbr\u003eA: The module is designed for two tachometer input channels. Shielded signal cable routing is recommended to reduce induced electrical interference on speed measurement circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support analog retransmission to external controllers?\u003cbr\u003eA: Yes. The hardware includes two 4-20 mA analog outputs for transmission of measured process variables to supervisory systems or external control equipment.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module suitable for hot replacement while energized?\u003cbr\u003eA: The supplied specifications do not define hot-swap support. Power isolation is recommended before module insertion or removal to prevent communication interruption or terminal arcing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module on the specified XM terminal base using the designated mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate tachometer input wiring from relay output and power conductors to minimize electrical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields at a single grounding reference point inside the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify 24 VDC supply polarity before energizing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain enclosure ventilation sufficient for continuous 7 W thermal dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect screw terminal retention during commissioning in applications with continuous machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43421692690522,"sku":"1440-SPD02-01RB","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1440-SPD02-012.jpg?v=1779854460","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1440-spd02-01rb-xm-220-speed-measurement-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}