{"product_id":"allen-bradley-1440-tun06-00re-xm-361-universal-temperature-module","title":"Allen-Bradley 1440-TUN06-00RE XM-361 Universal Temperature Module","description":"\u003ch1\u003eAllen-Bradley 1440-TUN06-00RE XM-361 Universal Temperature Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1440-TUN06-00RE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1440-TUN06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Temperature Module utilized to execute multi-channel thermal signal acquisition across XM DeviceNet monitoring platforms. The module accepts RTD and thermocouple sensor inputs through six universal channels while transferring process temperature data through DeviceNet communication and 4-20 mA output interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1440-TUN06-00RE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eXM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Temperature Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eXM-361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 universal input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003eThermocouples J, K, T, E, R, S, B, N; RTDs Pt100, Pt1000, Ni120, Cu10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA outputs, DeviceNet communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC Class 2\/SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 V continuous; tested at 1500 VAC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e98 x 95 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.64 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConformal coating per IPC-A-610C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eModule status and communication LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeviceNet Integration and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe XM-361 module exchanges thermal measurement data through DeviceNet network architecture while maintaining six independent sensor acquisition channels within a single DIN-rail footprint. This channel density permits consolidated monitoring of bearing housings, motor windings, casing surfaces, and lubrication systems without distributing separate single-loop transmitters across the control enclosure.\u003c\/p\u003e\n\u003cp\u003eThe module supports mixed thermocouple and RTD installations, reducing field hardware variation during retrofit projects. DeviceNet communication permits cyclic data transfer between XM monitoring assemblies and supervisory PLC or DCS platforms using deterministic industrial network timing structures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1440-TUN06-00RE provide direct relay trip outputs?\u003cbr\u003eA: The supplied specifications reference DeviceNet communication and 4-20 mA outputs only. No onboard relay trip outputs are listed.\u003c\/p\u003e\n\u003cp\u003eQ: Can different sensor technologies be connected simultaneously?\u003cbr\u003eA: Yes. The module supports multiple thermocouple and RTD sensor types across its six universal input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What installation method is specified for the module?\u003cbr\u003eA: The module is designed for DIN-rail mounting with field wiring terminated through associated XM terminal base assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute thermocouple wiring separately from motor power conductors to reduce induced electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity and terminate cable shields at a single grounding reference point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify thermocouple polarity before energizing the module to prevent inverted temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse matched RTD lead configurations and consistent conductor lengths where multi-point comparison measurements are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module inside an enclosure that limits conductive dust and moisture accumulation around terminal areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm DeviceNet node addressing and bus termination before connecting the module to an active network segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43422087610458,"sku":"1440-TUN06-00RE","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1440-TUN06-00RE2.jpg?v=1779861065","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1440-tun06-00re-xm-361-universal-temperature-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}