{"product_id":"allen-bradley-1440-vdrs06-06rh-xm-120-dynamic-measurement-module","title":"Allen-Bradley 1440-VDRS06-06RH XM-120 Dynamic Measurement Module","description":"\u003ch1\u003eAllen-Bradley 1440-VDRS06-06RH XM-120 Dynamic Measurement Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for vibration and dynamic signal acquisition in XM condition monitoring networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1440-VDRS06-06RH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1440-VDRS06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDynamic Measurement Module) provides direct electrical execution for multi-channel machine condition analysis, buffered signal routing, and DeviceNet data exchange. The module supports six dynamic inputs for eddy current probes, accelerometers, and velocity transducers operating within rotating equipment monitoring assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe provided documentation identifies the unit as a fixed XM-120 monitoring module. No official suffix segmentation or ordering matrix was specified for the 1440-VDRS06-06RH catalog number.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1440-VDRS06-06RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eXM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eXM-120 Dynamic Measurement Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 98 x 95 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC Class 2 \/ SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot explicitly specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 dynamic channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003eEddy current probes, accelerometers, velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003eOne isolated buffered output per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Functions\u003c\/td\u003e\n\u003ctd\u003eConfigurable alarm and trip outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coating per IPC-A-610C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEPE Excitation\u003c\/td\u003e\n\u003ctd\u003e2.69 mA constant current from 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Arrangement\u003c\/td\u003e\n\u003ctd\u003eTwo isolated banks of three outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial monitoring module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeviceNet Integration and Backplane Signal Distribution\u003c\/h3\u003e\n\u003cp\u003eThe XM-120 module exchanges measurement data through DeviceNet communication layers used within Allen-Bradley XM condition monitoring architectures. Buffered outputs are electrically isolated in two independent banks, reducing interaction between adjacent vibration channels during high-frequency signal transmission.\u003c\/p\u003e\n\u003cp\u003eThe module supports direct routing of dynamic waveform signals to external analyzers without interrupting DeviceNet communication traffic. IEPE excitation current output at 2.69 mA permits direct connection of compatible accelerometer assemblies operating from the 24 VDC excitation source.\u003c\/p\u003e\n\u003cp\u003eDIN-rail installation permits multi-module I\/O density expansion within a shared monitoring enclosure. Expansion layouts require consistent DeviceNet trunk termination and shield continuity to maintain deterministic communication stability between monitoring nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1440-VDRS06-06RH support hot insertion while energized?\u003cbr\u003eA: The supplied documentation does not specify hot-swap capability. Standard industrial practice is to remove field power before installing or removing XM series monitoring modules.\u003c\/p\u003e\n\u003cp\u003eQ: Can the buffered outputs be connected simultaneously to external analyzers and the control network?\u003cbr\u003eA: Yes. The buffered outputs are intended for external diagnostic instrumentation while DeviceNet communication continues independently through the network interface.\u003c\/p\u003e\n\u003cp\u003eQ: What sensor types are supported by the dynamic input channels?\u003cbr\u003eA: The module supports eddy current probes, IEPE accelerometers, and velocity sensors compatible with the XM-120 input circuitry and excitation requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module on grounded DIN rail assemblies with adequate spacing for heat dissipation and cable routing. Separate dynamic signal wiring from motor power conductors and variable frequency drive output cables to reduce conducted electrical noise.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields at a single designated grounding point inside the enclosure to minimize ground loop currents. Maintain consistent polarity and channel labeling during probe termination to prevent cross-channel signal assignment errors.\u003c\/p\u003e\n\u003cp\u003eDeviceNet trunk and drop wiring must follow approved network length and termination practices. Verify network resistance and shield continuity before energizing the monitoring rack. IEPE sensor wiring should not share conduit space with relay output conductors or high-current switching circuits.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43422115070042,"sku":"1440-VDRS06-06RH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1440-VDRS06-06RH2.jpg?v=1779861394","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1440-vdrs06-06rh-xm-120-dynamic-measurement-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}