{"product_id":"allen-bradley-1444-tscx02-02rb-tachometer-signal-conditioner-expansion-module","title":"Allen-Bradley 1444-TSCX02-02RB Tachometer Signal Conditioner Expansion Module","description":"\u003ch1\u003eAllen-Bradley 1444-TSCX02-02RB Tachometer Signal Conditioner Expansion Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for tachometer signal conditioning in the Dynamix 1444 Integrated Machinery Monitoring System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1444-TSCX02-02RB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1444-TSCX02-02RB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTachometer Signal Conditioner Expansion Module) provides direct electrical execution for speed, phase, and rotational signal processing across Dynamix 1444 platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 tachometer input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 TTL buffered speed outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 conditioned outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 local bus outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequires terminal base (B) and removable plug connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMust be connected to a 1444 series Dynamic Measurement Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1444-TSCX02-02RB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.46 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65 × 54 × 154 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTachometer Signal Conditioner Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003eTTL signals, eddy current probes, NPN\/PNP proximity switches, magnetic pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003e2 TTL speed outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConditioned Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003e1444 series local bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Measurement Range\u003c\/td\u003e\n\u003ctd\u003e1 RPM to 1,200,000 RPM depending on configured range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 RPM to ±160 RPM depending on speed range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-35 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e2 m\/s² up to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, C-UL-US, RCM, ATEX, IECEx, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 60068, IEC 61000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry Compliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Speed Signal Processing Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1444-TSCX02-02RB supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough synchronized local bus communication with Dynamix 1444 monitoring modules. Internal conditioning circuitry processes raw tachometer signals from multiple sensor technologies while maintaining stable pulse shaping and phase reference timing. Firmware compatibility across the 1444 platform permits expansion without modification to primary measurement module configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the module operate independently without a Dynamic Measurement Module?\u003cbr\u003eA: No. The 1444-TSCX02-02RB must be connected to a compatible Dynamix 1444 Dynamic Measurement Module through the local bus.\u003c\/p\u003e\n\u003cp\u003eQ: Which tachometer sensor types are supported?\u003cbr\u003eA: The module accepts TTL voltage signals, eddy current probe systems, magnetic pickups, and NPN\/PNP proximity sensors.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide raw signal outputs in addition to conditioned outputs?\u003cbr\u003eA: Yes. Two buffered TTL outputs are available for external monitoring or diagnostic use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module on the specified terminal base (B) before energizing the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute tachometer signal cables separately from relay and motor power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded cabling for low-level speed sensor signals and terminate shields at one grounding point only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify local bus connector alignment before applying supply voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain enclosure vibration limits within specified operating conditions to prevent intermittent terminal contact. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43426308849754,"sku":"1444-TSCX02-02RB","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1444-TSCX02-02RB2.jpg?v=1779939603","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1444-tscx02-02rb-tachometer-signal-conditioner-expansion-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}