{"id":43426740961370,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1492-ACABLE080UA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1492-ACABLE080UA Pre-assembled I\/O Cable","public_title":null,"options":["Default Title"],"price":12300,"weight":635,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1492-ACABLE080UA Pre-assembled I/O Cable

Configured for shielded analog signal transmission between PLC I/O assemblies and interface terminals in ControlLogix wiring architectures, the Allen-Bradley 1492-ACABLE080UA (1492-ACABLE080UA pre-assembled I/O cable) provides direct electrical execution. The cable assembly is factory-terminated for Bulletin 1756 analogue I/O, RTD, and thermocouple input module connectivity through the 1492 wiring system platform.

Suffix Breakdown & Model Matrix

The supplied documentation identifies the unit as a fixed catalog configuration. No additional suffix matrix or configurable option breakdown is specified for this model.

Hardware Specifications

Parameter Specification
Model 1492-ACABLE080UA
Brand Allen-Bradley
Series 1492 I/O Wiring Systems
Product Type Pre-assembled I/O Cable
Application Bulletin 1756 analogue I/O / RTD / thermocouple input modules
Cable Length 8.0 meters
Connector Type D-sub style to wiring interface
Shielding Shielded cable assembly
Voltage Rating 300 V
Current Rating 1 A per conductor
Conductor Size 24 AWG
Insulation Material PVC
Cable Color Black
Operating Temp -20 deg C to +75 deg C
Power Consumption Passive cable assembly; no internal power consumption
Weight 1.40 lbs
Dimensions Not specified in supplied documentation
Compliance UL, CSA, CE
Origin United States

EtherNet/IP Deterministic Signal Routing Characteristics

The 1492 cable assembly is intended for low-noise signal continuity between field termination hardware and ControlLogix analogue input modules. Shield continuity across the cable path reduces susceptibility to conducted electrical interference generated by adjacent motor feeders, VFD output conductors, and high-current switching devices.

Within Bulletin 1756 RTD and thermocouple input installations, the factory-terminated cable geometry maintains conductor consistency and minimizes terminal landing variation introduced during manual assembly. The assembly supports deterministic analogue signal transport by reducing wiring impedance variation between controller-side and field-side terminations.

Frequently Asked Questions

Q: Can the 1492-ACABLE080UA be connected or disconnected while the associated I/O module remains energized?
A: The cable itself contains no active circuitry, but connection or removal under energized conditions should follow the controller and terminal base hot-swap procedures defined for the associated Bulletin 1756 I/O hardware.

Q: What is the function of the cable shield in analogue and thermocouple applications?
A: The shield provides attenuation of externally induced electrical noise and should be bonded according to the grounding method specified for the associated analogue input module and panel grounding scheme.

Q: Is field termination required on this cable assembly?
A: No. The assembly is supplied with factory-installed connectors intended to reduce manual conductor termination and associated wiring variation.


Field Installation Guidelines

  • Route analogue cable assemblies separately from AC motor feeders, contactor wiring, and VFD output conductors.

  • Maintain shield continuity through the designated grounding point defined by the control cabinet grounding architecture.

  • Avoid excessive bend radius near connector transitions to prevent conductor stress at molded termination points.

  • Verify connector keying and pin orientation before insertion into Bulletin 1756 interface hardware.

  • Do not pull the cable assembly by the connector housing during cabinet installation or maintenance procedures.

  • Inspect cable shielding and outer PVC insulation for compression damage before energizing the control panel.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products