{"product_id":"allen-bradley-1492-cable050x-1492-i-o-wiring-system-pre-wired-cable-assembly","title":"Allen-Bradley 1492-CABLE050X 1492 I\/O Wiring System Pre-wired Cable Assembly","description":"\u003ch1\u003eAllen-Bradley 1492-CABLE050X 1492 I\/O Wiring System Pre-wired Cable Assembly\u003c\/h1\u003e\n\u003cp\u003eConfigured for PLC I\/O signal routing in Allen-Bradley interface wiring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1492-CABLE050X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1492-CABLE050X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epre-wired cable assembly) provides direct electrical interconnection between PLC modules and IFM termination hardware. The assembly integrates shielded 22 AWG multi-conductor cabling with factory-terminated connectors to reduce field termination variability and maintain deterministic signal continuity across 1492 I\/O wiring architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eModel Variant\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1492-CABLE050X\u003c\/td\u003e\n\u003ctd\u003ePre-wired digital connection cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003e22 AWG multi-conductor shielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Count\u003c\/td\u003e\n\u003ctd\u003e20 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1492-CABLE050X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePre-wired Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1492 I\/O Wiring Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded multi-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Conductors\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD-sub connector to terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly; no internal power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePLC I\/O to IFM signal interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEtherNet\/IP Wiring Integrity and Backplane Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1492-CABLE050X is intended for deterministic PLC I\/O wiring arrangements where connector repeatability and conductor mapping accuracy affect backplane data integrity. Shield continuity across the cable assembly reduces susceptibility to induced electrical noise generated by adjacent motor drives, relay switching circuits, and high-current cabinet conductors.\u003c\/p\u003e\n\u003cp\u003eFactory-defined conductor termination eliminates manual point-to-point crimping inconsistencies that can introduce intermittent channel faults during high-density I\/O deployment. The cable pinout is aligned with compatible Allen-Bradley IFM and PLC interface configurations to maintain consistent signal assignment across modular cabinet installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1492-CABLE050X require additional shield grounding in the control cabinet?\u003c\/strong\u003e\u003cbr\u003eA: The cable shield should be bonded according to the cabinet grounding scheme and the associated PLC or IFM installation manual. Shield termination is typically performed at one designated grounding reference point to minimize ground loop current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the cable assembly be hot-swapped while the PLC rack remains energized?\u003c\/strong\u003e\u003cbr\u003eA: Connector insertion or removal under energized conditions depends on the attached PLC and IFM hardware specifications. Standard practice is to isolate field and rack power before disconnecting pre-wired I\/O assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation condition most commonly affects signal integrity on multi-conductor PLC cables?\u003c\/strong\u003e\u003cbr\u003eA: Routing the cable parallel to high-voltage or variable frequency drive output conductors without separation distance can increase electromagnetic interference coupling into low-level I\/O channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify connector keying and pin orientation before applying insertion force to D-sub interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain cable bend radius consistent with industrial control cabinet wiring practice to prevent conductor stress near connector terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute shielded I\/O cables separately from motor power feeders, contactor outputs, and VFD output wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse DIN-rail cable retention or strain relief hardware where cabinet vibration or repeated maintenance access is expected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm conductor continuity and shield bonding with insulation and continuity testing prior to commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid excessive cable tension at IFM terminal interfaces to prevent connector deformation or intermittent contact resistance increases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43431514505306,"sku":"1492-CABLE050X","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1492-CABLE050X2.jpg?v=1780026450","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1492-cable050x-1492-i-o-wiring-system-pre-wired-cable-assembly","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}