{"product_id":"allen-bradley-1492-xim2024-16rf-relay-interface-module","title":"Allen-Bradley 1492-XIM2024-16RF Relay Interface Module","description":"\u003ch1\u003eAllen-Bradley 1492-XIM2024-16RF Relay Interface Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1492-XIM2024-16RF\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1492-XIM2024-16RF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay Interface Module, operates as a dedicated hardware component for isolated 24 VDC input signal interfacing and wiring conversion within ControlLogix migration and digital I\/O distribution systems. The module incorporates 16 relays with fused protection and provides a 20-pin master interface for field signal termination and relay isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1492-XIM2024-16RF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1492-XIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003e20-pin Relay Master Digital IFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Quantity\u003c\/td\u003e\n\u003ctd\u003e16 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eResistive fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating per Circuit\u003c\/td\u003e\n\u003ctd\u003eTypically 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Capacity\u003c\/td\u003e\n\u003ctd\u003eApproximately 12 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eLED status and fuse condition indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003eUp to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, C-UL-US, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003ePLC-5 to ControlLogix migration applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Wiring Conversion Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1492-XIM2024-16RF supports I\/O migration projects by consolidating 16 isolated input circuits into a structured relay interface assembly. The 20-pin master interface reduces field rewiring requirements when replacing legacy PLC hardware. Individual relay channels and fused protection permit separation of field circuits while maintaining organized signal routing between existing plant wiring and modern ControlLogix I\/O platforms.\u003c\/p\u003e\n\u003cp\u003eThe module functions as an interface layer and does not modify PLC scan execution, controller communications, or network determinism. System performance remains dependent on the connected ControlLogix controller and associated I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1492-XIM2024-16RF provide channel-to-channel isolation?\u003c\/strong\u003e\u003cbr\u003eA: The module is specified with 16 isolated input channels utilizing relay interface circuitry and individual fused protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can blown fuse conditions be identified without disconnecting field wiring?\u003c\/strong\u003e\u003cbr\u003eA: Yes. LED indicators are provided to assist maintenance personnel in identifying input activity and fuse status during inspection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require firmware updates?\u003c\/strong\u003e\u003cbr\u003eA: No. The 1492-XIM2024-16RF is an interface module and no firmware upgrade requirements are specified in the available documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDe-energize all connected field circuits before installation or maintenance activities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit on a properly grounded DIN rail according to panel layout requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate low-voltage signal wiring from higher-energy conductors to minimize electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify polarity of all 24 VDC input connections before energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that replacement fuses match the original electrical characteristics specified for the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain access to LED indicators to simplify diagnostic and maintenance procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute relay interface wiring to avoid excessive mechanical stress on terminal connections and cable assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow grounding and shielding practices specified for the associated ControlLogix and field I\/O equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43441775280218,"sku":"1492-XIM2024-16RF","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1492-XIM2024-16RF2.jpg?v=1780381328","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1492-xim2024-16rf-relay-interface-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}