Skip to content
Allen-Bradley 1492-XIM2024-16RF Relay Interface Module

Allen-Bradley 1492-XIM2024-16RF Relay Interface Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1492-XIM2024-16RF

  • Condition: In stock

  • Product Type: Relay Interface Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 703g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43441775280218,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1492-XIM2024-16RF","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1492-XIM2024-16RF Relay Interface Module","public_title":null,"options":["Default Title"],"price":12300,"weight":703,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1492-XIM2024-16RF Relay Interface Module

The Allen-Bradley 1492-XIM2024-16RF, also cataloged as the 1492-XIM2024-16RF Relay Interface Module, operates as a dedicated hardware component for isolated 24 VDC input signal interfacing and wiring conversion within ControlLogix migration and digital I/O distribution systems. The module incorporates 16 relays with fused protection and provides a 20-pin master interface for field signal termination and relay isolation.

Hardware Specifications

Parameter Specification
Model 1492-XIM2024-16RF
Brand Allen-Bradley
Product Type Relay Interface Module
Series 1492-XIM
Interface Type 20-pin Relay Master Digital IFM
Input Channels 16 isolated inputs
Relay Quantity 16 relays
Voltage Rating 24 VDC
Fuse Type Resistive fuse per channel
Current Rating per Circuit Typically 2 A
Module Current Capacity Approximately 12 A max
Indicators LED status and fuse condition indicators
Mounting DIN-rail mountable
Operating Temp 0 deg C to 60 deg C
Storage Temp Up to 85 deg C
Certifications CE, UL, C-UL-US, FM
Compatibility PLC-5 to ControlLogix migration applications
Weight 1.55 lb

I/O Density Scaling and Wiring Conversion Architecture

The 1492-XIM2024-16RF supports I/O migration projects by consolidating 16 isolated input circuits into a structured relay interface assembly. The 20-pin master interface reduces field rewiring requirements when replacing legacy PLC hardware. Individual relay channels and fused protection permit separation of field circuits while maintaining organized signal routing between existing plant wiring and modern ControlLogix I/O platforms.

The module functions as an interface layer and does not modify PLC scan execution, controller communications, or network determinism. System performance remains dependent on the connected ControlLogix controller and associated I/O modules.

Frequently Asked Questions

Q: Does the 1492-XIM2024-16RF provide channel-to-channel isolation?
A: The module is specified with 16 isolated input channels utilizing relay interface circuitry and individual fused protection.

Q: Can blown fuse conditions be identified without disconnecting field wiring?
A: Yes. LED indicators are provided to assist maintenance personnel in identifying input activity and fuse status during inspection.

Q: Does the module require firmware updates?
A: No. The 1492-XIM2024-16RF is an interface module and no firmware upgrade requirements are specified in the available documentation.


Field Installation Guidelines

  • De-energize all connected field circuits before installation or maintenance activities.

  • Mount the unit on a properly grounded DIN rail according to panel layout requirements.

  • Separate low-voltage signal wiring from higher-energy conductors to minimize electrical interference.

  • Verify polarity of all 24 VDC input connections before energization.

  • Confirm that replacement fuses match the original electrical characteristics specified for the application.

  • Maintain access to LED indicators to simplify diagnostic and maintenance procedures.

  • Route relay interface wiring to avoid excessive mechanical stress on terminal connections and cable assemblies.

  • Follow grounding and shielding practices specified for the associated ControlLogix and field I/O equipment.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products