{"product_id":"allen-bradley-1606-xle120e-2-1606-xle-series-power-supply","title":"Allen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply","description":"\u003ch1\u003eAllen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply\u003c\/h1\u003e\n\u003cp\u003eConfigured for regulated 24 VDC power conversion in industrial control power distribution networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1606-XLE120E-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1606-XLE120E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply) provides direct electrical execution. The unit is a DIN rail mounted switched-mode power supply rated at 120 W with adjustable 24-28 VDC output. It supports two-phase AC input configurations and delivers up to 5 A continuous output current.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1606-XLE120E-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a fixed catalog number within the 1606-XLE Series. No official suffix decomposition is provided in the source data; therefore, no further suffix interpretation is included.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1606-XLE120E-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched-Mode Regulated Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1606-XLE Essential Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage AC\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC \/ 200-240 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Input Specification\u003c\/td\u003e\n\u003ctd\u003e380-480 VAC, Two-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage DC\u003c\/td\u003e\n\u003ctd\u003e210-375 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eAdjustable 24-28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreset Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5 A Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eApproximately 88% Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;25 A @ 120 VAC, \u0026lt;40 A @ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-Up Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;=20 ms at Full Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple and Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOverload, Short-Circuit, Internal Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eLED Status Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 508, IEC 60950, EN 60950, EN 50178, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact DIN Rail Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on load; 120 W rated output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Flash Compatibility Considerations\u003c\/h3\u003e\n\u003cp\u003eAs a standalone power conversion device, the 1606-XLE120E-2 does not require firmware synchronization with PLC backplanes or communication processors. When installed in systems containing EtherNet\/IP, Profinet, or proprietary controller networks, the power supply functions independently from network firmware revision management. Output regulation and startup behavior remain isolated from controller firmware update procedures.\u003c\/p\u003e\n\u003cp\u003eThe unit is intended for panel-level DC power distribution and can supply field I\/O assemblies, communication adapters, and controller racks provided that total current demand remains within the specified 5 A continuous output rating.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1606-XLE120E-2 support hot replacement while energized?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe documentation does not specify hot-swap capability. Standard practice is to remove input power and verify discharge of connected loads before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this power supply be connected to redundant power architectures?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRedundant operation may be implemented through external redundancy modules designed for DC power sharing and isolation. Redundancy performance depends on the selected external hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the unit require forced-air cooling?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The specified cooling method is natural convection. Adequate clearance around ventilation surfaces should be maintained according to panel design practices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit vertically on a properly grounded DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate AC input wiring from low-voltage DC output conductors to reduce conducted noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize conductors according to local electrical codes and expected load current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAllow unobstructed airflow around the enclosure to support convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify protective earth continuity before energizing the power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConsider upstream protection devices capable of accommodating the specified inrush current characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen installed near variable frequency drives or high-current switching equipment, route power and signal cables in separate wireways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43447916068954,"sku":"1606-XLE120E-2","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1606-XLE120E-22.jpg?v=1780471319","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1606-xle120e-2-1606-xle-series-power-supply","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}