Allen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply

Allen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1606-XLE120E-2

  • Condition: In stock

  • Product Type: 1606-XLE Series Power Supply

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 499g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43447916068954,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1606-XLE120E-2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply","public_title":null,"options":["Default Title"],"price":12300,"weight":499,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1606-XLE120E-2 1606-XLE Series Power Supply

Configured for regulated 24 VDC power conversion in industrial control power distribution networks, the Allen-Bradley 1606-XLE120E-2 (1606-XLE120E power supply) provides direct electrical execution. The unit is a DIN rail mounted switched-mode power supply rated at 120 W with adjustable 24-28 VDC output. It supports two-phase AC input configurations and delivers up to 5 A continuous output current.

Suffix Breakdown & Model Matrix

The supplied documentation identifies 1606-XLE120E-2 as a fixed catalog number within the 1606-XLE Series. No official suffix decomposition is provided in the source data; therefore, no further suffix interpretation is included.

Hardware Specifications

Parameter Specification
Model 1606-XLE120E-2
Brand Allen-Bradley
Product Type Switched-Mode Regulated Power Supply
Series 1606-XLE Essential Power
Mounting DIN Rail
Input Voltage AC 100-120 VAC / 200-240 VAC, 47-63 Hz
Alternate Input Specification 380-480 VAC, Two-Phase
Input Voltage DC 210-375 VDC
Output Voltage Adjustable 24-28 VDC
Preset Output Voltage 24 VDC +/-0.5%
Output Current 5 A Continuous
Rated Output Power 120 W
Efficiency Approximately 88% Typical
Inrush Current <25 A @ 120 VAC, <40 A @ 230 VAC
Hold-Up Time >=20 ms at Full Load
Ripple and Noise <100 mVpp
Protection Overload, Short-Circuit, Internal Fuse
Cooling Method Natural Convection
Indicators LED Status Indicator
Operating Temp -10 to +70 deg C
Certifications UL 508, IEC 60950, EN 60950, EN 50178, CE
Dimensions Compact DIN Rail Housing
Weight 1.10 lbs
Power Consumption Dependent on load; 120 W rated output

Firmware Flash Compatibility Considerations

As a standalone power conversion device, the 1606-XLE120E-2 does not require firmware synchronization with PLC backplanes or communication processors. When installed in systems containing EtherNet/IP, Profinet, or proprietary controller networks, the power supply functions independently from network firmware revision management. Output regulation and startup behavior remain isolated from controller firmware update procedures.

The unit is intended for panel-level DC power distribution and can supply field I/O assemblies, communication adapters, and controller racks provided that total current demand remains within the specified 5 A continuous output rating.

Frequently Asked Questions

Q: Does the 1606-XLE120E-2 support hot replacement while energized?
A: The documentation does not specify hot-swap capability. Standard practice is to remove input power and verify discharge of connected loads before replacement.

Q: Can this power supply be connected to redundant power architectures?
A: Redundant operation may be implemented through external redundancy modules designed for DC power sharing and isolation. Redundancy performance depends on the selected external hardware.

Q: Does the unit require forced-air cooling?
A: No. The specified cooling method is natural convection. Adequate clearance around ventilation surfaces should be maintained according to panel design practices.


Field Installation Guidelines

  • Mount the unit vertically on a properly grounded DIN rail.

  • Separate AC input wiring from low-voltage DC output conductors to reduce conducted noise coupling.

  • Size conductors according to local electrical codes and expected load current.

  • Allow unobstructed airflow around the enclosure to support convection cooling.

  • Verify protective earth continuity before energizing the power supply.

  • Consider upstream protection devices capable of accommodating the specified inrush current characteristics.

  • When installed near variable frequency drives or high-current switching equipment, route power and signal cables in separate wireways.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured