{"product_id":"allen-bradley-1606-xls480ee-switched-mode-power-supply","title":"Allen-Bradley 1606-XLS480EE Switched Mode Power Supply","description":"\u003ch1\u003eAllen-Bradley 1606-XLS480EE Switched Mode Power Supply\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1606-XLS480EE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1606-XLS480EE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSwitched Mode Power Supply utilized to execute AC-to-DC power conversion and regulated 24 VDC distribution across Bulletin 1606 power supply platforms. The module accepts 200-240 VAC input and delivers up to 20 A output current with an adjustable 24 VDC output for industrial control circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe provided documentation identifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1606-XLS480EE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a fixed catalog number within the Bulletin 1606-XLS series. No official suffix decomposition is specified in the source data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1606-XLS480EE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBulletin 1606-XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Mode Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput dependent on load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e200-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Support\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eSpring Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Signal\u003c\/td\u003e\n\u003ctd\u003eDC-OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Profile\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Generation\u003c\/td\u003e\n\u003ctd\u003eMinimal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eAC\/DC Conversion and DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Control System Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1606-XLS480EE is a power conversion device rather than a programmable controller module and therefore does not require application firmware flashing during normal operation. Within Allen-Bradley control architectures, the module supplies regulated 24 VDC power to PLC, communication, and field device circuits. Integration with EtherNet\/IP or other deterministic industrial networks occurs through the powered control equipment rather than through the power supply itself.\u003c\/p\u003e\n\u003cp\u003eThe DC-OK signaling output can be incorporated into monitoring circuits to provide power status feedback. Proper sizing of the supply relative to downstream load current is required when supporting distributed I\/O assemblies and communication infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1606-XLS480EE support hot replacement while energized?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe supplied specifications do not indicate hot-swap capability. Power isolation and compliance with plant lockout procedures should be followed before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module accept DC input voltage?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The provided specifications identify operation from 200-240 VAC input only and explicitly state that DC input voltage is not supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the DC-OK signal?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DC-OK output provides status indication that the output voltage is present and within the module's operating range, allowing connection to supervisory monitoring circuits.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit on a suitable DIN rail or panel arrangement according to the installation manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between AC input conductors and 24 VDC output wiring to reduce conducted noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify spring-clamp terminal engagement before energizing the circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect protective earth according to local electrical codes and panel design requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute signal wiring separately from high-current motor and drive cables where practical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that total connected load current does not exceed the rated 20 A output capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse appropriately sized conductors based on installation standards and expected load current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43449776996442,"sku":"1606-XLS480EE","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1606-XLS480EE2.jpg?v=1780545593","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1606-xls480ee-switched-mode-power-supply","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}