Skip to content
Allen-Bradley 1606-XLS480EE Switched Mode Power Supply

Allen-Bradley 1606-XLS480EE Switched Mode Power Supply

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1606-XLS480EE

  • Condition: In stock

  • Product Type: Switched Mode Power Supply

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 934g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43449776996442,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1606-XLS480EE","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1606-XLS480EE Switched Mode Power Supply","public_title":null,"options":["Default Title"],"price":12300,"weight":934,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1606-XLS480EE Switched Mode Power Supply

The Allen-Bradley 1606-XLS480EE serves as the primary 1606-XLS480EE Switched Mode Power Supply utilized to execute AC-to-DC power conversion and regulated 24 VDC distribution across Bulletin 1606 power supply platforms. The module accepts 200-240 VAC input and delivers up to 20 A output current with an adjustable 24 VDC output for industrial control circuits.

Suffix Breakdown & Model Matrix

The provided documentation identifies 1606-XLS480EE as a fixed catalog number within the Bulletin 1606-XLS series. No official suffix decomposition is specified in the source data.

Hardware Specifications

Parameter Specification
Model 1606-XLS480EE
Brand Allen-Bradley
Product Series Bulletin 1606-XLS
Product Type Switched Mode Power Supply
Weight 2.06 lbs
Power Consumption Input dependent on load
Input Voltage 200-240 VAC
Input Phase Single-phase AC
DC Input Support Not supported
Output Voltage 24 VDC, adjustable
Output Current 20 A
Output Power 480 W
Terminals Spring Clamp
Status Signal DC-OK
Installation Profile Compact
Heat Generation Minimal
Function AC/DC Conversion and DC Power Supply

Firmware Flash Compatibility and Control System Integration

The 1606-XLS480EE is a power conversion device rather than a programmable controller module and therefore does not require application firmware flashing during normal operation. Within Allen-Bradley control architectures, the module supplies regulated 24 VDC power to PLC, communication, and field device circuits. Integration with EtherNet/IP or other deterministic industrial networks occurs through the powered control equipment rather than through the power supply itself.

The DC-OK signaling output can be incorporated into monitoring circuits to provide power status feedback. Proper sizing of the supply relative to downstream load current is required when supporting distributed I/O assemblies and communication infrastructure.

Frequently Asked Questions

Q: Does the 1606-XLS480EE support hot replacement while energized?
A: The supplied specifications do not indicate hot-swap capability. Power isolation and compliance with plant lockout procedures should be followed before replacement.

Q: Can the module accept DC input voltage?
A: No. The provided specifications identify operation from 200-240 VAC input only and explicitly state that DC input voltage is not supported.

Q: What is the purpose of the DC-OK signal?
A: The DC-OK output provides status indication that the output voltage is present and within the module's operating range, allowing connection to supervisory monitoring circuits.


Field Installation Guidelines

  • Mount the unit on a suitable DIN rail or panel arrangement according to the installation manual.

  • Maintain separation between AC input conductors and 24 VDC output wiring to reduce conducted noise coupling.

  • Verify spring-clamp terminal engagement before energizing the circuit.

  • Connect protective earth according to local electrical codes and panel design requirements.

  • Route signal wiring separately from high-current motor and drive cables where practical.

  • Confirm that total connected load current does not exceed the rated 20 A output capability.

  • Use appropriately sized conductors based on installation standards and expected load current.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products