{"product_id":"allen-bradley-1606-xls960e-3-performance-power-supply","title":"Allen-Bradley 1606-XLS960E-3 Performance Power Supply","description":"\u003ch1\u003eAllen-Bradley 1606-XLS960E-3 Performance Power Supply\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1606-XLS960E-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1606-XLS960E-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply utilized to execute regulated 24-28 VDC power conversion across industrial control system platforms. The unit converts three-phase 380-480 VAC input power into a stabilized DC output with up to 960 W capacity and supports DIN-rail installation within control enclosures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1606-XLS960E-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a fixed catalog number within the 1606-XLS Performance Power product family. No official suffix decomposition is specified in the provided data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1606-XLS960E-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1606-XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Mode Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380-480 VAC, 3-phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Option\u003c\/td\u003e\n\u003ctd\u003e600 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e1.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eAdjustable 24-28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e40 A at 24 VDC; 34.3 A at 28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 95.2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 100 mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-Up Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-35 Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOverload, Short-Circuit, Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 508, IEC\/EN 60950, EN 50178, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e124 x 110 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput dependent, rated output 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Power System Integration\u003c\/h3\u003e\n\u003cp\u003eWithin distributed PLC and automation architectures, the 1606-XLS960E-3 functions as a DC power source for controllers, communication modules, and field I\/O assemblies. The regulated 24-28 VDC output supports stable backplane and peripheral power distribution. When deployed with approved redundancy accessories, the unit can participate in redundant DC supply architectures while maintaining output isolation between parallel power sources.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1606-XLS960E-3 support hot replacement during operation?\u003c\/strong\u003e\u003cbr\u003eA: The supplied documentation does not specify hot-swap capability. Power isolation and de-energization procedures should follow the equipment manufacturer's maintenance requirements before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output current is available at different output voltage settings?\u003c\/strong\u003e\u003cbr\u003eA: The power supply delivers up to 40 A at 24 VDC and up to 34.3 A at 28 VDC while remaining within its 960 W power rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection mechanisms are integrated into the unit?\u003c\/strong\u003e\u003cbr\u003eA: The power supply includes overload protection, short-circuit protection, and overvoltage protection functions as specified by the manufacturer.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the unit on a DIN-35 rail with adequate mechanical support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain enclosure ventilation to allow heat dissipation around the power supply housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify phase connections and input voltage before energizing the device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute DC output conductors separately from high-noise switching or motor power cables where practical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten field wiring terminals according to the manufacturer's installation instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm grounding continuity between the power supply, panel ground, and enclosure grounding system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAllow sufficient clearance around ventilation openings and avoid obstructing airflow paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43454905679962,"sku":"1606-XLS960E-3","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1606-XLS960E-32.jpg?v=1780640273","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1606-xls960e-3-performance-power-supply","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}