{"product_id":"allen-bradley-1715-c2-backplane-extender-cable","title":"Allen Bradley 1715-C2 Backplane Extender Cable","description":"\u003ch1\u003eAllen Bradley 1715-C2 Backplane Extender Cable\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1715-C2\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-C2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBackplane Extender Cable, operates as a dedicated hardware component for extending backplane connectivity within 1715 Redundant I\/O networks. It provides a direct physical interface between I\/O bases over a 2 m span.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 V supply nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBackplane Extender Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 N·m (0.37 lb·ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrewdriver Width\u003c\/td\u003e\n\u003ctd\u003e0.4 x 2.0 mm (0.0156 x 0.0781 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eRedundant I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Support\u003c\/h3\u003e\n\u003cp\u003eThe 1715-C2 cable maintains signal integrity across the extended backplane connection for redundant I\/O modules. It ensures proper bus termination and alignment between base units, supporting deterministic data transfer between connected modules. The cable is compatible with standard 1715 I\/O bases and does not interfere with firmware flash operations across the linked modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 1715-C2 compatible with all 1715 I\/O bases?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The cable is designed to extend backplane connections between standard 1715 I\/O base units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the required torque for terminal screws?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScrew terminals must be tightened to 0.5 N·m (0.37 lb·ft) using a compatible screwdriver with 0.4 x 2.0 mm width.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the cable length be extended beyond 2 meters?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe approved design specifies a 2 m length; longer runs may compromise backplane communication integrity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the cable along a clear path between I\/O bases, avoiding sharp bends or pinch points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure connectors are fully seated in the base units before energizing the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify torque on all screws to maintain secure electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep the cable away from high-voltage or high-current wiring to minimize induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck proper alignment and seating of the backplane bus interface to prevent data errors in redundant I\/O configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain mechanical strain relief at both ends to prevent cable pull or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43455261573210,"sku":"1715-C2","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-C22.jpg?v=1780645337","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-c2-backplane-extender-cable","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}