{"product_id":"allen-bradley-1715-of8i-8-channel-analog-output-module","title":"Allen-Bradley 1715-OF8I 8 Channel Analog Output Module","description":"\u003ch1\u003eAllen-Bradley 1715-OF8I 8 Channel Analog Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for 4-20 mA analog signal transmission in Allen-Bradley PLC\/DCS networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-OF8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1715-OF8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channel Analog Output Module) provides direct electrical execution across eight independent output channels with precision current control.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 1715-OF8I is a fixed catalog model within the 1715 I\/O series. No further suffixes or ordering variations are indicated in the documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-OF8I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8 Channel Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1715 I\/O Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDIN rail mount standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +60 deg C (operating), max surrounding 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eControl LSB: 0.98 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eMonitor LSB: 3.9 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Measurement Error\u003c\/td\u003e\n\u003ctd\u003e± 0.30% + 10 µA (after 1 yr @ 40 deg C); ± 0.35% + 10 µA (after 2 yrs @ 40 deg C); ± 0.44% + 10 µA (after 5 yrs @ 40 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.01% + 0.1 µA per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2 series: thermal shock, dry heat, operating cold; 10-95% noncondensing RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \u0026amp; Vibration\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10-500 Hz, shock up to 30 g installed, 50 g uninstalled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Class A; IEC 61000-4-2\/3\/4\/5 immunity standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 1715-OF8I interfaces with Allen-Bradley backplane bus systems, supporting deterministic I\/O cycles and predictable latency across eight analog output channels. Backplane communication velocity licensing ensures precise timing for process control loops. I\/O density scaling allows multiple modules to share the same bus without signal degradation. Firmware flash compatibility provides support for software revisions without requiring physical module replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum operating temperature for the 1715-OF8I?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates within -25 deg C to +60 deg C, with a maximum surrounding air temperature of 70 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module handle hot-swap replacement on the DIN rail?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard installation procedures should be followed; while the module is designed for DIN rail mounting, hot-swap is not recommended without verifying the bus power state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the expected accuracy drift over time?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasurement error begins at ±0.30% + 10 µA (after 1 year at 40 deg C) and may increase to ±0.44% + 10 µA after 5 years at 40 deg C.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module vertically on a DIN rail to maintain thermal dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog output cables separately from high-power AC lines to minimize interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure shielded signal cables are properly grounded at a single point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate clearance around the module for air circulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify proper bus termination and backplane connections before energizing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid exceeding maximum operating temperature and relative humidity limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect and tighten all terminal screws during commissioning and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43455168512090,"sku":"1715-OF8I","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-OF8I2.jpg?v=1780642638","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-of8i-8-channel-analog-output-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}