{"product_id":"allen-bradley-1715-tadof8-termination-assembly-8-ch-ao-duplex","title":"Allen-Bradley 1715-TADOF8 Termination Assembly 8 CH AO Duplex","description":"\u003ch1\u003eAllen-Bradley 1715-TADOF8 Termination Assembly 8 CH AO Duplex\u003c\/h1\u003e\n\u003cp\u003eConfigured for analog output signal termination in Allen-Bradley 1715 Redundant I\/O systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-TADOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1715-TADOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Assembly) provides direct physical and electrical execution between field analog output circuits and the backplane interface. The assembly supports eight analog output channels with shielded field wiring and is intended for duplex I\/O architectures requiring structured field termination and signal routing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TADOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a fixed catalog number. No official suffix decomposition or model matrix information is provided in the available data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-TADOF8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly, 8 Channel Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e8 Analog Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0...24 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18...32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Voltage Slew Rate\u003c\/td\u003e\n\u003ctd\u003eNo limit identified within compliance voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation (System)\u003c\/td\u003e\n\u003ctd\u003e3.6 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation (Field Loop)\u003c\/td\u003e\n\u003ctd\u003e0.64 W per field loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous, basic insulation, I\/O ports to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Category\u003c\/td\u003e\n\u003ctd\u003eCategory 2 on shielded signal ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Type\u003c\/td\u003e\n\u003ctd\u003eShielded copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e0.33...1.5 mm2 (22...16 AWG) solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e85 deg C minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H)\u003c\/td\u003e\n\u003ctd\u003e4.2 cm x 13.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEtherNet\/IP Infrastructure and I\/O Density Considerations\u003c\/h3\u003e\n\u003cp\u003eThe 1715 platform is designed for high-density distributed I\/O deployment where termination assemblies provide the physical interface between field devices and redundant I\/O electronics. Within duplex architectures, the 1715-TADOF8 supports organized analog output wiring while maintaining compatibility with platform backplane communication mechanisms. Signal routing is performed through the termination assembly without introducing additional channel-to-channel isolation, making shield management and proper grounding practices important during installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1715-TADOF8 provide isolation between individual analog output channels?\u003c\/strong\u003e\u003cbr\u003eA: No. The module documentation specifies no isolation between individual I\/O ports. Isolation is provided only between the I\/O ports and the backplane at the specified insulation level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What conductor types can be connected to the termination assembly?\u003c\/strong\u003e\u003cbr\u003eA: The assembly accepts shielded solid or stranded copper conductors from 0.33 mm2 to 1.5 mm2 (22 AWG to 16 AWG) with a minimum temperature rating of 85 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the assembly installed inside a protective enclosure?\u003c\/strong\u003e\u003cbr\u003eA: The unit is supplied as an open-style assembly. Installation within a suitable industrial control enclosure is required to provide environmental and personnel protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the assembly in a properly grounded industrial control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded signal cables for all analog output connections as specified by the wiring category requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to the control system grounding philosophy to minimize conducted noise and ground loop effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate analog output wiring from power distribution conductors, motor leads, and variable frequency drive cables where practical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify conductor size compatibility before termination and ensure terminal screws are tightened according to manufacturer recommendations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm field loop voltage remains within the specified 18...32 VDC operating range prior to commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform insulation and continuity checks before energizing the analog output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate clearance around the assembly to allow wiring access and inspection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43465325346906,"sku":"1715-TADOF8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-TADIF161.jpg?v=1780906743","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-tadof8-termination-assembly-8-ch-ao-duplex","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}