Allen-Bradley 1715-TAS0F8I Termination Assembly

Allen-Bradley 1715-TAS0F8I Termination Assembly

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1715-TAS0F8I

  • Condition: In stock

  • Product Type: Termination Assembly

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 133g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43465348776026,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1715-TAS0F8I","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1715-TAS0F8I Termination Assembly","public_title":null,"options":["Default Title"],"price":12300,"weight":133,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1715-TAS0F8I Termination Assembly

The Allen-Bradley 1715-TAS0F8I, also cataloged as the 1715-TAS0F8I Termination Assembly, operates as a dedicated hardware component for analog output field signal termination and channel protection within the Bulletin 1715 Redundant I/O System. It provides the physical wiring interface, per-channel fusing, and isolation required for 0-24 mA output circuits associated with the 1715-OF8I analog output module.

Suffix Breakdown & Model Matrix

The catalog number 1715-TAS0F8I is identified as a dedicated termination assembly for the 1715-OF8I isolated analog output module. No official suffix decomposition or ordering matrix is specified in the supplied documentation.

Hardware Specifications

Parameter Specification
Model 1715-TAS0F8I
Brand Allen-Bradley
Origin United States
Product Type Termination Assembly for Analog Output Module
Supported Module 1715-OF8I
System Platform Bulletin 1715 Redundant I/O System
Signal Range 0-24 mA per channel
Typical Application Range 4-20 mA
Operating Voltage 18-32 VDC
Isolation Voltage 50 V continuous
Dielectric Test 500 VAC for 60 s
Channel Protection 50 mA fuse per channel
Wiring Type Shielded copper wire
Wire Size 22-16 AWG solid or stranded
Conductor Rating 85 deg C minimum
Screw Torque 0.5 Nm
Recommended Screwdriver Width 0.4 x 2.0 mm flathead
Weight 0.133 kg
Environmental Protection Conformal coated
Environmental Standards ANSI/ISA-S71.04-2013 Class G1-G3, IEC 60654-4, UL746E, MIL-I-46058C

EtherNet/IP and Redundant I/O Infrastructure

Within the 1715 Redundant I/O architecture, the 1715-TAS0F8I functions as the field termination interface for isolated analog output channels. The assembly supports high I/O density deployments by consolidating signal wiring, fuse protection, and isolation functions into a dedicated termination platform. Its design aligns with the deterministic data handling requirements of redundant EtherNet/IP-based control infrastructures while maintaining separation between field circuits and backplane connections.

Frequently Asked Questions

Q: Does the 1715-TAS0F8I provide individual channel protection?
A: Yes. The assembly incorporates a 50 mA fuse for each output channel, providing independent protection against field-side overload conditions.

Q: Can unshielded conductors be used for analog output wiring?
A: The documented wiring specification calls for shielded copper conductors. Shielded wiring assists in reducing noise coupling into low-level analog signal circuits.

Q: Is the 1715-TAS0F8I interchangeable with termination assemblies for other 1715 analog output modules?
A: The assembly is specified for use with the 1715-OF8I isolated analog output module. Compatibility with other modules should be verified against the applicable Rockwell Automation documentation.


Field Installation Guidelines

  • Install the termination assembly inside a grounded industrial enclosure suitable for the operating environment.

  • Verify that the connected module is a 1715-OF8I before applying field wiring.

  • Use shielded copper conductors rated for at least 85 deg C.

  • Route analog output cables separately from motor feeders, contactor wiring, and other high-energy conductors.

  • Terminate cable shields according to the site grounding philosophy to avoid unintended ground-loop currents.

  • Inspect all channel fuses prior to commissioning and replace only with equivalent specified ratings.

  • Apply the recommended terminal torque to prevent conductor loosening and terminal damage.

  • Confirm field supply voltage remains within the specified 18-32 VDC operating range before energization.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products