{"product_id":"allen-bradley-1715-tas0f8i-termination-assembly","title":"Allen-Bradley 1715-TAS0F8I Termination Assembly","description":"\u003ch1\u003eAllen-Bradley 1715-TAS0F8I Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-TAS0F8I\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TAS0F8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Assembly, operates as a dedicated hardware component for analog output field signal termination and channel protection within the Bulletin 1715 Redundant I\/O System. It provides the physical wiring interface, per-channel fusing, and isolation required for 0-24 mA output circuits associated with the 1715-OF8I analog output module.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TAS0F8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis identified as a dedicated termination assembly for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-OF8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolated analog output module. No official suffix decomposition or ordering matrix is specified in the supplied documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-TAS0F8I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly for Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Module\u003c\/td\u003e\n\u003ctd\u003e1715-OF8I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eBulletin 1715 Redundant I\/O System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0-24 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Application Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Protection\u003c\/td\u003e\n\u003ctd\u003e50 mA fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003eShielded copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e22-16 AWG solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Rating\u003c\/td\u003e\n\u003ctd\u003e85 deg C minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Screwdriver Width\u003c\/td\u003e\n\u003ctd\u003e0.4 x 2.0 mm flathead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Standards\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA-S71.04-2013 Class G1-G3, IEC 60654-4, UL746E, MIL-I-46058C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEtherNet\/IP and Redundant I\/O Infrastructure\u003c\/h3\u003e\n\u003cp\u003eWithin the 1715 Redundant I\/O architecture, the 1715-TAS0F8I functions as the field termination interface for isolated analog output channels. The assembly supports high I\/O density deployments by consolidating signal wiring, fuse protection, and isolation functions into a dedicated termination platform. Its design aligns with the deterministic data handling requirements of redundant EtherNet\/IP-based control infrastructures while maintaining separation between field circuits and backplane connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1715-TAS0F8I provide individual channel protection?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The assembly incorporates a 50 mA fuse for each output channel, providing independent protection against field-side overload conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can unshielded conductors be used for analog output wiring?\u003c\/strong\u003e\u003cbr\u003eA: The documented wiring specification calls for shielded copper conductors. Shielded wiring assists in reducing noise coupling into low-level analog signal circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 1715-TAS0F8I interchangeable with termination assemblies for other 1715 analog output modules?\u003c\/strong\u003e\u003cbr\u003eA: The assembly is specified for use with the 1715-OF8I isolated analog output module. Compatibility with other modules should be verified against the applicable Rockwell Automation documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the termination assembly inside a grounded industrial enclosure suitable for the operating environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the connected module is a 1715-OF8I before applying field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded copper conductors rated for at least 85 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog output cables separately from motor feeders, contactor wiring, and other high-energy conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to the site grounding philosophy to avoid unintended ground-loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect all channel fuses prior to commissioning and replace only with equivalent specified ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply the recommended terminal torque to prevent conductor loosening and terminal damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm field supply voltage remains within the specified 18-32 VDC operating range before energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43465348776026,"sku":"1715-TAS0F8I","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-TADIB16D2.jpg?v=1780906382","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-tas0f8i-termination-assembly","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}