{"product_id":"allen-bradley-1715-tasib16d-termination-assembly","title":"Allen-Bradley 1715-TASIB16D Termination Assembly","description":"\u003ch1\u003eAllen-Bradley 1715-TASIB16D Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eConfigured for redundant digital input signal termination in the Bulletin 1715 Redundant I\/O System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-TASIB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1715-TASIB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Assembly) provides direct physical and electrical interface for the 1715-IB16D 16-point digital input module, including per-channel isolation and fusing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TASIB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specified as a dedicated termination assembly for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-IB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-point digital input module. No official sub-models or ordering matrix are indicated in the provided documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-TASIB16D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly for Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Module\u003c\/td\u003e\n\u003ctd\u003e1715-IB16D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eBulletin 1715 Redundant I\/O System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC (nominal 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Protection\u003c\/td\u003e\n\u003ctd\u003e2 A fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003eShielded copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e22-16 AWG solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Rating\u003c\/td\u003e\n\u003ctd\u003e85 deg C minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Screwdriver Width\u003c\/td\u003e\n\u003ctd\u003e0.4 x 2.0 mm flathead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Standards\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA-S71.04-2013 Class G1-G3, IEC 60654-4, UL746E, MIL-I-46058C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Redundant Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1715-TASIB16D supports high-density digital input deployment by consolidating field wiring, fusing, and channel isolation into a single termination assembly. It interfaces with the 1715 backplane, maintaining separation between field signals and backplane circuits to support deterministic network behavior and seamless integration into redundant control architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1715-TASIB16D provide per-channel protection for all digital inputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, each input channel is protected by a 2 A fuse, ensuring overload protection at the field wiring level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can unshielded wires be used for installation?\u003c\/strong\u003e\u003cbr\u003eA: Shielded copper conductors are required to minimize noise interference. Unshielded conductors may compromise signal integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the termination assembly hot-swappable with the 1715-IB16D module?\u003c\/strong\u003e\u003cbr\u003eA: The assembly is intended for fixed wiring connections. Hot-swapping procedures must follow the Rockwell Automation Bulletin 1715 guidelines for module removal and insertion.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the module is a 1715-IB16D before wiring to the termination assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMount the assembly in an appropriately grounded industrial enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded copper conductors rated at 85 deg C or higher for all input connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute digital input wiring separately from high-power conductors to minimize crosstalk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect cable shields in accordance with site grounding policies to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque terminal screws to the specified 0.5 Nm to maintain secure connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify fuses are installed correctly and rated for 2 A per channel prior to system energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm input voltage remains within 18-32 VDC during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43465355133018,"sku":"1715-TASIB16D","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-TADIF16.jpg?v=1780906743","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-tasib16d-termination-assembly","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}