{"product_id":"allen-bradley-1715-tasof8-analog-output-termination-assembly","title":"Allen-Bradley 1715-TASOF8 Analog Output Termination Assembly","description":"\u003ch1\u003eAllen-Bradley 1715-TASOF8 Analog Output Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-TASOF8\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TASOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTermination Assembly, operates as a dedicated hardware component for channel-level analog output termination within 1715 Redundant I\/O systems. It provides physical wiring interface and redundancy support for the 1715-OF8I analog output module.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-TASOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fixed catalog number supporting a single 1715-OF8I analog output module. No additional suffix variants or configuration matrix are specified in available documentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-TASOF8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003e1715 Redundant I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Module\u003c\/td\u003e\n\u003ctd\u003e1715-OF8I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-channel (AOTA Dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eEthernet 1 \u0026amp; Ethernet 2 for redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eHealthy, Ready, Run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e233 × 126 × 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFits 1715-A3IO base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eConformal coating, UKCA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Style\u003c\/td\u003e\n\u003ctd\u003eOpen-style termination assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial control conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling in Redundant Analog Output Systems\u003c\/h3\u003e\n\u003cp\u003eThe 1715-TASOF8 integrates with the Allen-Bradley 1715 Redundant I\/O platform, allowing high-density analog output connectivity. By separating module electronics from field wiring, the termination assembly supports dual-path redundancy and facilitates channel-level diagnostics. This design enables scalable I\/O deployment while maintaining operational continuity during module maintenance or failure conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1715-TASOF8 operate without the 1715-OF8I module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The assembly requires a 1715-OF8I analog output module and a 1715-A3IO base unit for proper operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicators are available for diagnostics?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly provides channel status indicators including Healthy, Ready, and Run, along with network and rack diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the recommended mounting method?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the termination assembly on the 1715-A3IO base unit using standard mounting points. Ensure wiring is correctly terminated and shielded where applicable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the 1715-TASOF8 on the 1715-A3IO base unit following mechanical alignment guides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all analog output channels (CH0–CH7) are clearly wired according to channel identity labels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation from high-voltage power circuits to reduce electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify dual-channel redundancy paths are connected properly to Ethernet ports 1 and 2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm operating environment adheres to industrial temperature and humidity standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply conformal coating handling precautions when performing field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect all terminal connections for torque compliance and mechanical stability before energizing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43468610437210,"sku":"1715-TASOF8","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1715-TASOF82.jpg?v=1780984554","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1715-tasof8-analog-output-termination-assembly","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}