Skip to content
Allen-Bradley 1734-OB8S/B POINT Guard I/O Safety Digital Output Module

Allen-Bradley 1734-OB8S/B POINT Guard I/O Safety Digital Output Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1734-OB8S/B

  • Condition: In stock

  • Product Type: POINT Guard I/O Safety Digital Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 59g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43479183589466,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1734-OB8S\/B","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1734-OB8S\/B POINT Guard I\/O Safety Digital Output Module","public_title":null,"options":["Default Title"],"price":12300,"weight":59,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1734-OB8S/B POINT Guard I/O Safety Digital Output Module

The Allen-Bradley 1734-OB8S/B serves as the primary 1734-OB8S Safety Digital Output Module utilized to execute safety-rated sourcing output switching across CIP Safety and POINT Guard I/O platforms. The module provides eight sourcing outputs with integrated diagnostic monitoring, electronic short-circuit protection, and test pulse functionality for safety-related control circuits.

Suffix Breakdown & Model Matrix

Parameter Specification
Base Model 1734-OB8S
Hardware Revision /B
Product Family POINT Guard I/O
Module Type Safety Digital Output Module

The supplied documentation identifies 1734-OB8S/B as a Series B hardware revision. No additional ordering suffix matrix is specified.

Hardware Specifications

Parameter Specification
Model 1734-OB8S/B
Brand Allen-Bradley
Product Family POINT Guard I/O
Module Type Safety Digital Output Module
Outputs per Module 8
Output Type Current sourcing
Maximum Output Current 1 A per channel
Aggregate Module Current 8 A
Aggregate Current per Terminal Base 4 A at 40 deg C
Operating Voltage Range 19.2 VDC to 28.8 VDC
Nominal Voltage 24 VDC
Residual Voltage Drop Less than 0.6 V
Leakage Current 0.1 mA maximum
Short-Circuit Detection High, low, and cross-circuit fault detection
Short-Circuit Protection Electronic
Reaction Time Less than 6.2 ms
POINTBus Current Consumption 190 mA at 5 V
Isolation Voltage 50 V continuous basic insulation
Power Consumption 3.02 W
Thermal Dissipation 10.32 BTU/hr
Operating Temp -20 deg C to +55 deg C
Storage Temp -40 deg C to +85 deg C
Enclosure Type Open-style
Wiring Category Category 2 signal ports

CIP Safety Network and I/O Redundancy Characteristics

The 1734-OB8S/B operates within CIP Safety architectures using safety-related communication between POINT Guard I/O and GuardLogix controllers. The module supports dual-channel safety circuit implementation and incorporates diagnostic mechanisms for cross-circuit, low-side, and high-side fault detection. Its eight-output configuration increases safety I/O density while maintaining deterministic safety state execution through the distributed I/O infrastructure.

Frequently Asked Questions

Q: What diagnostic faults can the module detect?
A: The module supports detection of high-side short circuits, low-side short circuits, and cross-circuit wiring faults.

Q: What is the maximum reaction time of the safety outputs?
A: The specified reaction time is less than 6.2 ms.

Q: Which terminal bases are compatible with the 1734-OB8S/B?
A: Compatible terminal bases include 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS, 1734-TOP3, and 1734-TOP3S.


Field Installation Guidelines

  • Verify that the field supply voltage remains within the specified 19.2 VDC to 28.8 VDC operating range.

  • Install the module only within approved POINT Guard I/O assemblies and compatible terminal bases.

  • Route safety circuit wiring separately from non-safety control and power conductors.

  • Validate safety channel wiring and fault-monitoring functions during commissioning.

  • Maintain enclosure conditions within the specified operating temperature limits.

  • Confirm grounding continuity and shield termination practices according to the project safety design.

  • Perform controller and module configuration verification before placing safety outputs into service.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products