Allen-Bradley 1734SC-IF4U POINT I/O Universal Analog Input Module

Allen-Bradley 1734SC-IF4U POINT I/O Universal Analog Input Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1734SC-IF4U

  • Condition: In stock

  • Product Type: POINT I/O Universal Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 77g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43479271899226,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1734SC-IF4U","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1734SC-IF4U POINT I\/O Universal Analog Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":77,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1734SC-IF4U POINT I/O Universal Analog Input Module

Configured for multi-signal analog acquisition in POINT I/O distributed control networks, the Allen-Bradley 1734SC-IF4U (1734SC-IF4U Universal Analog Input Module) provides direct electrical processing of voltage, current, thermocouple, RTD, and resistance inputs. The module supports channel-level configuration, integrated cold junction compensation, selectable filtering, and field-to-backplane isolation for mixed analog measurement applications.

Suffix Breakdown & Model Matrix

The supplied documentation identifies 1734SC-IF4U as a fixed catalog number. No official suffix breakdown or ordering matrix is specified in the provided data.

Hardware Specifications

Parameter Specification
Model 1734SC-IF4U
Brand Allen-Bradley
Manufacturer Spectrum Controls for Rockwell Automation POINT I/O
Product Type Universal Analog Input Module
Product Family POINT I/O
Channels 4 analog inputs
Input Types Voltage, Current, Thermocouple, RTD, Resistance
Voltage Input Ranges +/-50 mV, +/-100 mV, 0-5 V, 1-5 V, 0-10 V, +/-10 V
Current Input Ranges 0-20 mA, 4-20 mA
Thermocouple Types J, K, T, E
RTD Types PT385/3916, Ni618/672, NiFe518, Cu426
Resolution 18 bits (filter dependent)
Accuracy +/-20 uV (50 mV range); +/-0.6 deg C Type J TC; +/-0.5 deg C 1 kOhm RTD
Filtering 4 selectable frequencies per channel
Update Time 37 ms to 512 ms
Isolation Voltage 50 VDC field-to-backplane; 10 VDC channel-to-channel
Input Impedance 253 Ohm (current); 5-10 MOhm (voltage/temperature inputs)
Overvoltage Protection +24 VDC continuous
Overcurrent Protection 32 mA continuous
Backplane Current 20 mA @ 24 VDC; 15 mA @ 5 VDC
Power Consumption Not specified
Thermal Dissipation 1.0 W max
Operating Temp -20 deg C to +55 deg C
Storage Temp -40 deg C to +85 deg C
Humidity 5-95% non-condensing
Weight 0.17 lb

I/O Density Scaling and Distributed Analog Acquisition

The 1734SC-IF4U consolidates multiple analog signal types into a single POINT I/O module. Voltage, current, thermocouple, RTD, and resistance measurements can be configured independently at the channel level, reducing the number of dedicated analog modules required within a distributed I/O assembly. This approach increases I/O density while maintaining compatibility with POINTBus backplane communication architectures.

Frequently Asked Questions

Q: Can different input signal types be used on the same module simultaneously?
A: Yes. The module supports independent channel configuration, allowing different supported measurement types to be assigned according to application requirements.

Q: Does the module provide thermocouple compensation functions?
A: Yes. Cold junction compensation is integrated for thermocouple measurement applications.

Q: Is channel-to-channel isolation provided?
A: The module provides 50 VDC field-to-backplane isolation and 10 VDC channel-to-channel isolation as specified in the technical data.


Field Installation Guidelines

  • Install the module inside a suitable industrial enclosure that provides environmental protection and electrical safety.

  • Separate low-level thermocouple and RTD wiring from motor, relay, and high-current conductors to minimize electrical noise.

  • Ground cable shields according to plant grounding practices and maintain consistent shield termination methods throughout the installation.

  • Verify input type configuration before energizing field circuits to prevent measurement errors.

  • Route temperature sensor wiring away from variable frequency drive output cables and other high-frequency noise sources.

  • Maintain terminal connections according to manufacturer torque recommendations for the selected terminal base.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products