{"product_id":"allen-bradley-1734sc-if4u-point-i-o-universal-analog-input-module","title":"Allen-Bradley 1734SC-IF4U POINT I\/O Universal Analog Input Module","description":"\u003ch1\u003eAllen-Bradley 1734SC-IF4U POINT I\/O Universal Analog Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for multi-signal analog acquisition in POINT I\/O distributed control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734SC-IF4U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1734SC-IF4U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Analog Input Module) provides direct electrical processing of voltage, current, thermocouple, RTD, and resistance inputs. The module supports channel-level configuration, integrated cold junction compensation, selectable filtering, and field-to-backplane isolation for mixed analog measurement applications.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734SC-IF4U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a fixed catalog number. No official suffix breakdown or ordering matrix is specified in the provided data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734SC-IF4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSpectrum Controls for Rockwell Automation POINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Thermocouple, RTD, Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-50 mV, +\/-100 mV, 0-5 V, 1-5 V, 0-10 V, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003ePT385\/3916, Ni618\/672, NiFe518, Cu426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e18 bits (filter dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-20 uV (50 mV range); +\/-0.6 deg C Type J TC; +\/-0.5 deg C 1 kOhm RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering\u003c\/td\u003e\n\u003ctd\u003e4 selectable frequencies per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e37 ms to 512 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 VDC field-to-backplane; 10 VDC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e253 Ohm (current); 5-10 MOhm (voltage\/temperature inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e+24 VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003e32 mA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e20 mA @ 24 VDC; 15 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.0 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Distributed Analog Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe 1734SC-IF4U consolidates multiple analog signal types into a single POINT I\/O module. Voltage, current, thermocouple, RTD, and resistance measurements can be configured independently at the channel level, reducing the number of dedicated analog modules required within a distributed I\/O assembly. This approach increases I\/O density while maintaining compatibility with POINTBus backplane communication architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can different input signal types be used on the same module simultaneously?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The module supports independent channel configuration, allowing different supported measurement types to be assigned according to application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide thermocouple compensation functions?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Cold junction compensation is integrated for thermocouple measurement applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is channel-to-channel isolation provided?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 50 VDC field-to-backplane isolation and 10 VDC channel-to-channel isolation as specified in the technical data.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module inside a suitable industrial enclosure that provides environmental protection and electrical safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate low-level thermocouple and RTD wiring from motor, relay, and high-current conductors to minimize electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround cable shields according to plant grounding practices and maintain consistent shield termination methods throughout the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify input type configuration before energizing field circuits to prevent measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute temperature sensor wiring away from variable frequency drive output cables and other high-frequency noise sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain terminal connections according to manufacturer torque recommendations for the selected terminal base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43479271899226,"sku":"1734SC-IF4U","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1734SC-IF4U2.jpg?v=1781149207","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1734sc-if4u-point-i-o-universal-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}