{"product_id":"allen-bradley-1747-c13-slc-cable","title":"Allen Bradley 1747-C13 SLC Cable","description":"\u003ch1\u003eAllen Bradley 1747-C13 SLC Cable\u003c\/h1\u003e\n\u003cp\u003eConfigured for DH485 and RS-232C physical interconnection within SLC 500 communication chains, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1747-C13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1747-C13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSLC cable) provides direct electrical linking between interface modules and link couplers via DH485 network ports and J2 peripheral connectors in SLC controller architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1747-C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.09 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e0.91 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (no supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eSLC Communication Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eDH485 \/ RS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector End\u003c\/td\u003e\n\u003ctd\u003eJ2 Peripheral \/ DH485 Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSLC 500 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDH485 signal routing and RS-232C interface coupling behavior\u003c\/h3\u003e\n\u003cp\u003eThe 1747-C13 implements passive conductor routing for DH485 network signaling and RS-232C level interface adaptation through dedicated pin mapping across interface modules and link coupler ports. Signal transmission is constrained to defined impedance paths with no active conditioning, maintaining deterministic serial communication timing between SLC controllers and peripheral interface nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1747-C13 contain any active signal conversion electronics?\u003cbr\u003eA: No active circuitry is present. The cable functions as a passive physical layer interconnect for DH485 and RS-232C mapped signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable be used interchangeably with Ethernet cabling?\u003cbr\u003eA: No. Electrical pinout and signaling standards are specific to DH485 and RS-232C interfaces and are not compatible with Ethernet PHY layers.\u003c\/p\u003e\n\u003cp\u003eQ: Is the cable suitable for hot-plug operation during controller runtime?\u003cbr\u003eA: Hot-plug insertion is not supported. Connection should be performed under controlled communication idle state to avoid frame corruption.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify controller and interface module are in communication halt state before cable connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure DH485 and RS-232C ports are correctly identified prior to mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum bend radius consistent with industrial serial cabling practice.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute cable away from high-voltage conductors to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm continuity of shielding and reference ground at a single-point earth termination. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43538019319898,"sku":"1747-C13","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1747-C132.jpg?v=1782206731","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1747-c13-slc-cable","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}