{"product_id":"allen-bradley-1756-cfm-a-controllogix-configurable-flowmeter-module","title":"Allen-Bradley 1756-CFM\/A ControlLogix Configurable Flowmeter Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eAllen-Bradley 1756-CFM\/A ControlLogix Configurable Flowmeter Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eConfigured for configurable flow measurement and high-resolution frequency acquisition in ControlLogix platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-CFM\/A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1756-CFM\/A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlLogix Configurable Flowmeter Module) provides direct physical\/electrical execution. The module processes frequency, pulse, and flowmeter inputs through configurable acquisition modes and exchanges process data with ControlLogix controllers via backplane communication. Configuration and parameterization are performed within RSLogix 5000 or Studio 5000 environments, depending on system revision. Output behavior and measurement resolution are defined through software-controlled channel parameters and chassis-level execution timing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-CFM\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm x 5.1 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIEC 60068 compliant (range not specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eapprox. 1.2 A @ 5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs Supported\u003c\/td\u003e\n\u003ctd\u003eFrequency, pulse, flowmeter signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing configurable outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003eapprox. 1.2 A @ 5.1 V DC (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution frequency measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eRSLogix 5000 v16+ \/ Studio 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ControlLogix backplane architecture supports deterministic cyclic data exchange between chassis modules and controller tasks. For the 1756-CFM\/A, process data is mapped into controller memory through scheduled backplane transactions. I\/O update behavior is influenced by chassis scan rate, module configuration, and task priority allocation within the ControlLogix execution model. Firmware and module revision alignment is required to maintain backplane data consistency across mixed-module configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1756-CFM\/A be hot-swapped during chassis operation?\u003cbr\u003eA: Hot-swap capability depends on chassis power state and system configuration. Removal under power requires ControlLogix supported removal procedures to avoid backplane data corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is backplane current consumption determined for this module?\u003cbr\u003eA: Backplane load is primarily defined at 5.1 V DC and varies with configuration, signal processing mode, and active channel utilization within the module firmware.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility required between controller and module?\u003cbr\u003eA: Yes. The module revision must be compatible with ControlLogix controller firmware and Studio 5000 project version to ensure correct backplane data mapping.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module must be installed in a ControlLogix chassis with power removed prior to insertion. Verify correct slot alignment and full engagement of backplane connectors before energizing the system. Maintain separation between signal wiring and power conductors to reduce electrical noise coupling. Shield termination shall be connected to functional earth at the designated cabinet grounding point. Do not exceed chassis current limits defined by the ControlLogix power supply rating. Wiring must follow system-level grounding and cable routing rules defined for high-frequency signal acquisition modules.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43572435189850,"sku":"1756-CFM\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-CFMA2.jpg?v=1782789178","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1756-cfm-a-controllogix-configurable-flowmeter-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}