Skip to content
Allen-Bradley 1756-IB16D/A ControlLogix Diagnostic Digital Input Module

Allen-Bradley 1756-IB16D/A ControlLogix Diagnostic Digital Input Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-IB16D/A

  • Condition: In stock

  • Product Type: ControlLogix Diagnostic Digital Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 230g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43585761869914,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1756-IB16D\/A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1756-IB16D\/A ControlLogix Diagnostic Digital Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":230,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1756-IB16D/A ControlLogix Diagnostic Digital Input Module

Configured for DC discrete signal acquisition with embedded line and device fault monitoring in ControlLogix backplane systems, the Allen-Bradley 1756-IB16D/A (1756-IB16D diagnostic digital input module) provides direct electrical state sampling of 16-channel 24 V DC inputs while simultaneously executing diagnostic evaluation of wiring integrity and field device connectivity across ControlLogix chassis architectures.

Suffix Breakdown & Model Matrix

The provided configuration 1756-IB16D/A contains no further documented option code segmentation beyond the base diagnostic designator “D” and revision suffix “/A”. No additional structural or electrical sub-variants are defined in the supplied dataset.

Hardware Specifications

Parameter Specification
Model 1756-IB16D/A
Brand Allen-Bradley
Operating Temp 0 to 60 deg C
Channels 16 DC input channels
Input Voltage Range 10 to 30 V DC
Nominal Input Voltage 24 V DC
Input Current ~2.1 mA per point at 24 V DC
Backplane Current 110 mA at 5.1 V DC
Isolation 250 V (input to backplane)
Input Delay < 1 ms typical
Diagnostics Open-wire, short-circuit, device fault detection
Storage Temperature -40 to 85 deg C
Relative Humidity 5% to 95% non-condensing
Certifications UL, CE, CSA, C-Tick, KC
Slot Type ControlLogix chassis module

ControlLogix Backplane Diagnostics Execution Layer

The 1756-IB16D/A executes dual-path processing within the ControlLogix backplane: one path samples DC input state transitions, while the second path performs diagnostic evaluation of circuit continuity and impedance deviation. Diagnostic flags for open-wire and short-circuit conditions are generated at module level prior to controller tag mapping, enabling pre-processed fault signaling within deterministic backplane scan cycles. The module participates in chassis-level I/O scheduling where diagnostic and process data are synchronized per scan interval.

Frequently Asked Questions (FAQ)

Q: Does the 1756-IB16D/A perform diagnostics per channel independently?
A: Yes, each of the 16 DC input channels is individually monitored for open-wire and short-circuit conditions with channel-level fault reporting.

Q: Does diagnostic processing affect input scan time?
A: Input state acquisition remains < 1 ms typical; diagnostic evaluation runs in parallel within module-level processing and does not redefine backplane scan scheduling.

Q: Can the module operate in RIUP mode during diagnostics?
A: Removal and Insertion Under Power is supported at chassis level; diagnostic state is cleared and reinitialized upon module reinsertion and re-enumeration.


Field Installation Guidelines

  • Install module in a compatible ControlLogix chassis slot ensuring correct backplane alignment and locking.

  • Maintain separation between DC input wiring and high-noise switching conductors to preserve diagnostic signal integrity.

  • Use shielded cable where long field runs are present; terminate shield at single-point cabinet ground reference only.

  • Verify field device voltage range (10 to 30 V DC) prior to energizing input circuits.

  • Ensure stable terminal seating to avoid false diagnostic triggering due to intermittent contact resistance.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.