Skip to content
Allen-Bradley 1756-IB16DK Digital DC Input Module

Allen-Bradley 1756-IB16DK Digital DC Input Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-IB16DK

  • Condition: In stock

  • Product Type: Digital DC Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43600924541018,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1756-IB16DK","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1756-IB16DK Digital DC Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":450,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1756-IB16DK Digital DC Input Module

Configured for 16-channel discrete signal acquisition in ControlLogix backplane architectures, the Allen-Bradley 1756-IB16DK (1756-IB16DK Digital DC Input Module) provides direct electrical state capture from 12-24 VDC sink field devices across ControlLogix I/O networks. Input conditioning and diagnostic evaluation are executed at module level with per-point signal validation.

The module interfaces via ControlLogix chassis backplane, converting field-level DC transitions into controller-readable discrete input status with embedded diagnostic feedback per channel.

Suffix Breakdown & Model Matrix

The 1756-IB16DK is a single defined catalog model. No factory-documented suffix segmentation or option code matrix is provided in the source dataset. No decomposition logic is applied.

Hardware Specifications

Parameter Specification
Model 1756-IB16DK
Brand Allen-Bradley
Weight 0.45 kg
Power Consumption 5.8 W max at 60 deg C
Module Type Digital DC Input Module
Input Channels 16 diagnostic inputs
Input Voltage 12-24 VDC sink
Operating Voltage Range 10-30 VDC
Input Delay Time 4 ms plus selected filter time
Backplane Current 150 mA at 5 VDC
Off-state Leakage 1.5 mA per point max
Input Current Range 2 mA at 10 VDC to 13 mA at 30 VDC

ControlLogix Backplane & EtherNet/IP Signal Handling Characteristics

The module communicates through ControlLogix backplane cyclic scheduling, where input state updates are synchronized with controller scan execution. Backplane transaction timing is governed by chassis arbitration, supporting deterministic data exchange between I/O modules and CPU over the internal bus structure.

EtherNet/IP integration is indirect via controller-level communication, with I/O state representation mapped into cyclic assembly instances. Input data consistency is maintained through chassis-level scan alignment rather than field-level protocol timing.

I/O density scaling is implemented at chassis slot level, where each module contributes fixed channel capacity without dynamic reconfiguration of channel allocation. Firmware image consistency is tied to ControlLogix system firmware revision alignment, with module recognition dependent on backplane enumeration during chassis power-up.

Frequently Asked Questions (FAQ)

Q: Does the 1756-IB16DK support hot-swap insertion under backplane power?
A: The module supports removal and insertion within a powered ControlLogix chassis only when chassis configuration allows electronic keying and slot-based re-enumeration. Backplane voltage must remain stable during insertion to avoid input state invalidation.

Q: What is the backplane current impact per module?
A: The module draws 150 mA at 5 VDC from the ControlLogix backplane. Total chassis loading must account for cumulative current across all installed I/O modules.

Q: How is firmware compatibility handled across ControlLogix systems?
A: Module identification and operational state depend on ControlLogix firmware revision compatibility. Mismatch between chassis firmware and module revision can result in non-recognition during backplane enumeration.


Field Installation Guidelines

Install module only in ControlLogix 1756 chassis with stable backplane power distribution. Ensure terminal block seating (1756-TBCH or 1756-TBS6H) is fully engaged to maintain channel integrity across all 16 input points.

Field wiring shall use shielded twisted pair where external electrical noise is present. Shield termination must be bonded at single-point ground reference to avoid ground loop current injection into diagnostic channels.

Maintain separation between DC input wiring and high-energy switching conductors. Minimum routing separation should follow industrial control cabinet wiring practice to reduce induced coupling on low-voltage DC input lines.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products