{"product_id":"allen-bradley-1756-if8i-a-controllogix-analog-input-module","title":"Allen-Bradley 1756-IF8I\/A ControlLogix Analog Input Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eAllen-Bradley 1756-IF8I\/A ControlLogix Analog Input Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IF8I\/A\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-IF8I\/A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Module, operates as a dedicated hardware component for acquisition of voltage and current signals within ControlLogix chassis-based I\/O architecture. It provides 8 individually isolated input channels with per-channel signal conditioning for mixed analog measurement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-IF8I\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 15.2 cm x 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~120 mA at 5.1 VDC (backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e8 individually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e±10 V, 0–10 V, 0–5 V, 1–5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MΩ (voltage), 250 Ω (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eConfigurable, high-speed mode limited channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControlLogix Backplane Communication and Isolation Behavior\u003c\/h3\u003e\n\u003cp\u003eThe module executes analog conversion through channel-separated acquisition paths with internal isolation barriers between each input channel. Backplane exchange occurs via ControlLogix chassis communication bus with cyclic data refresh tied to slot configuration. Channel isolation prevents electrical coupling during mixed voltage\/current operation and reduces common-mode disturbance propagation across adjacent inputs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can each channel be configured independently for voltage or current input?\u003cbr\u003eA: Yes. Each of the 8 channels supports independent configuration for voltage or 0–20 mA \/ 4–20 mA current inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does channel-to-channel isolation affect scan timing or update rate?\u003cbr\u003eA: Isolation is implemented at the input stage; update rate behavior remains configurable but may limit simultaneous high-speed operation depending on channel selection.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane power dependency during full channel operation?\u003cbr\u003eA: The module draws approximately 120 mA at 5.1 VDC from the ControlLogix backplane; load is constant per module regardless of channel configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module into a compatible ControlLogix chassis slot with verified mechanical seating on the backplane connector. Use approved RTB or IFM termination assemblies for field wiring. Maintain segregation between analog signal cabling and high-voltage conductors to minimize induced coupling. Ensure shield termination is performed at a single system ground point to avoid ground loop formation across isolated channels. Power down chassis before insertion or removal of the module.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43602376196186,"sku":"1756-IF8I\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-IF8I1.jpg?v=1783317891","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1756-if8i-a-controllogix-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}