{"product_id":"allen-bradley-1756-it6i-controllogix-thermocouple-module","title":"Allen-Bradley 1756-IT6I ControlLogix Thermocouple Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-IT6I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a multi-channel thermocouple and millivolt analog input module designed for the Allen-Bradley ControlLogix platform. This module features six individually isolated input channels and integrated cold junction compensation (CJC), enabling precise temperature acquisition in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-accuracy thermal process monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IT6I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports a broad range of industry-standard thermocouple sensors including B, C, D, E, J, K, L, N, R, S, and T types. The module also accepts low-level millivolt signals for specialized measurement applications.\u003c\/p\u003e\n\u003cp\u003eWith 16-bit resolution, isolated channel architecture, and flexible floating-point or integer data processing, the module is suitable for critical temperature monitoring systems where signal integrity and electrical noise immunity are essential.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Thermocouple Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1756-IT6I\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e10612598172310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 Individually Isolated Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Sensor Input\u003c\/td\u003e\n\u003ctd\u003e1 Integrated Cold Junction Compensation (CJC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple and Millivolt Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, C, D, E, J, K, L (TXK\/XK), N, R, S, T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e16-Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Millivolt Range\u003c\/td\u003e\n\u003ctd\u003e-12 to +78 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Resolution Range\u003c\/td\u003e\n\u003ctd\u003e-12 to +30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Resolution\u003c\/td\u003e\n\u003ctd\u003e1.4 µV\/bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Resolution Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.7 µV\/bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Formats\u003c\/td\u003e\n\u003ctd\u003eInteger (2’s Complement), IEEE 32-Bit Floating Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Scan Time\u003c\/td\u003e\n\u003ctd\u003e10 ms Integer Mode (Millivolt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Point Scan Time\u003c\/td\u003e\n\u003ctd\u003e25 ms (Millivolt), 50 ms (Temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24V DC\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal 24V Backplane Load\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-Channel Isolated Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSix isolated thermocouple input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated cold junction compensation for accurate temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with major industrial thermocouple standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both thermocouple and millivolt signal measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution 16-bit analog conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFloating-point and integer data formatting options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for electrically noisy industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration with ControlLogix chassis systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFurnace and kiln temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoiler and steam system automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat treatment equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood processing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial thermal management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas process instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat sensor types are compatible with the 1756-IT6I?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports thermocouple types B, C, D, E, J, K, L, N, R, S, and T, as well as direct millivolt input signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module provide channel isolation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Each of the six analog input channels is individually isolated to reduce electrical interference and improve measurement stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the purpose of the integrated CJC sensor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe built-in cold junction compensation sensor improves thermocouple accuracy by compensating for terminal temperature variations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich terminal blocks can be used with this module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is compatible with Allen-Bradley 1756-TBNH and 1756-TBSH removable terminal blocks.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43324517908570,"sku":"1756-IT6I","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-IT6I2.jpg?v=1778124971","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1756-it6i-controllogix-thermocouple-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}