{"product_id":"allen-bradley-1756-l83es-guardlogix-5580-safety-controller","title":"Allen-Bradley 1756-L83ES GuardLogix 5580 Safety Controller","description":"\u003ch2\u003eAllen-Bradley 1756-L83ES GuardLogix 5580 Safety Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L83ES\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1756-L83ES\u003c\/strong\u003e GuardLogix Safety Controller, operates as a dedicated hardware component for safety logic execution and EtherNet\/IP communication within ControlLogix 5580 platforms. The controller provides 10 MB user memory, 5 MB safety memory, and integrated USB and Ethernet interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-L83ES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGuardLogix 5580 Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.81 lbs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCurrent draw: 5.0 mA at 1.2 VDC, 1.2 A at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Memory\u003c\/td\u003e\n\u003ctd\u003e5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e128,000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analog I\/O\u003c\/td\u003e\n\u003ctd\u003e4,000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Nodes\u003c\/td\u003e\n\u003ctd\u003e250 nodes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 USB 2.0 port, embedded Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100\/1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Networks\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, ControlNet, DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e31 standard tasks and 1 safety task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task\u003c\/td\u003e\n\u003ctd\u003e1,000 programs maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character alphanumeric display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Safety Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1756-L83ES uses the GuardLogix 5580 control architecture with integrated EtherNet\/IP communication capability. The embedded Ethernet interface supports deterministic network communication at 10 Mbps, 100 Mbps, and 1 Gbps speeds. The controller supports safety and standard communication paths through EtherNet\/IP, ControlNet, and DeviceNet interfaces.\u003c\/p\u003e\n\u003cp\u003eThe controller provides I\/O density scaling with support for up to 128,000 digital I\/O points and 4,000 analog I\/O points. Firmware and application compatibility are managed through the ControlLogix platform environment and Studio 5000 Logix Designer software.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What memory resources are available in the 1756-L83ES controller?\u003cbr\u003eA: The controller provides 10 MB of user memory and 5 MB of dedicated safety memory for GuardLogix safety application execution.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are integrated into the controller?\u003cbr\u003eA: The module includes one USB 2.0 programming port and one embedded Ethernet port supporting 10\/100\/1000 Mbps communication.\u003c\/p\u003e\n\u003cp\u003eQ: How many tasks can the controller execute?\u003cbr\u003eA: The controller supports up to 31 standard tasks and 1 safety task, with up to 1,000 programs per task.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the controller in a compatible ControlLogix chassis with the required power supply and backplane connections. Verify slot placement, grounding, and module seating before applying power.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication cables separately from high-voltage conductors and sources of electrical noise. Use appropriate shield grounding practices for industrial Ethernet wiring. Confirm firmware compatibility between the controller, communication modules, and Studio 5000 Logix Designer project before commissioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43617094697050,"sku":"1756-L83ES","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-L83ES2.jpg?v=1783494729","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1756-l83es-guardlogix-5580-safety-controller","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}