{"product_id":"allen-bradley-1756-ov32e-controllogix-digital-output-module","title":"Allen-Bradley 1756-OV32E ControlLogix Digital Output Module","description":"\u003ch2\u003eAllen-Bradley 1756-OV32E ControlLogix Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OV32E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1756-OV32E\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for DC sinking signal execution within ControlLogix I\/O systems. The module provides 32 electronically fused outputs for switching 10-30 VDC field devices with point-level protection and diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-OV32E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControlLogix Digital DC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBulletin 1756 ControlLogix I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDC sinking output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Output\u003c\/td\u003e\n\u003ctd\u003e0.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e16 outputs per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eElectronic point-level fusing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eField-side diagnostics and point fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e36-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd\u003eDirect-connect or rack-optimized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlLogix I\/O Backplane and Output Management\u003c\/h3\u003e\n\u003cp\u003eThe 1756-OV32E operates as a ControlLogix digital output module with high-density I\/O allocation. The module interfaces through the ControlLogix backplane for controller communication and provides deterministic output switching for DC field devices. Electronic fusing monitors individual output conditions and provides fault information through module diagnostics.\u003c\/p\u003e\n\u003cp\u003eThe module architecture supports I\/O density scaling within ControlLogix chassis configurations. Backplane communication and firmware compatibility are managed through the ControlLogix platform, allowing integration with EtherNet\/IP based deterministic control networks when used with compatible communication modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals can the 1756-OV32E control?\u003cbr\u003eA: The module controls DC sinking field loads operating within the 10-30 VDC range, including actuators, relays, solenoids, and indicator devices compatible with sinking outputs.\u003c\/p\u003e\n\u003cp\u003eQ: How are output faults managed on the module?\u003cbr\u003eA: Each output channel includes electronic fusing and point-level diagnostic feedback to indicate field-side fault conditions.\u003c\/p\u003e\n\u003cp\u003eQ: How many output points are available on one module?\u003cbr\u003eA: The module provides 32 digital output points arranged in two groups of 16 outputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a compatible ControlLogix chassis with the required backplane connection. Verify field wiring polarity and ensure that connected devices match the DC sinking output configuration.\u003c\/p\u003e\n\u003cp\u003eRoute output wiring separately from high-voltage power conductors and high-noise sources. Use appropriate grounding practices for cabinet wiring and connect cable shields according to the system grounding design. Confirm terminal connections, load current requirements, and field device compatibility before energizing the module.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43623567392858,"sku":"1756-OV32E","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-OV32E2.jpg?v=1783575993","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1756-ov32e-controllogix-digital-output-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}