{"id":43585679917146,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1756HP-TIME\/B","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1756HP-TIME\/B Time Synchronization Module","public_title":null,"options":["Default Title"],"price":12300,"weight":227,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1756HP-TIME/B Time Synchronization Module

Configured for precise time alignment in ControlLogix distributed control environments, the Allen-Bradley 1756HP-TIME/B (1756HP-TIME time synchronization module) provides direct physical and protocol-level time distribution across backplane-connected controllers and external network time sources. The module executes IEEE 1588 PTP and NTP time stamping functions within the ControlLogix 1756 chassis architecture, enabling deterministic event correlation across automation nodes.

Suffix Breakdown & Model Matrix

No official manufacturer-published suffix decomposition is provided for 1756HP-TIME/B. The “/B” revision is treated as hardware or firmware iteration within the HiProm module family without functional redefinition in available technical data.

Hardware Specifications

Parameter Specification
Model 1756HP-TIME/B
Brand Allen-Bradley
Dimensions Standard ControlLogix 1756 module form factor
Operating Temp 0 deg C to 60 deg C
Power Consumption < 2.5 W
Time Source GPS or external NTP/PTP
Protocols Supported IEEE 1588 Precision Time Protocol (PTP), NTP
Backplane Interface ControlLogix chassis backplane bus
Synchronization Accuracy Sub-millisecond class alignment across nodes

ControlLogix Backplane Time Distribution Behavior

The 1756HP-TIME/B operates as a time authority node within the ControlLogix backplane architecture, distributing synchronized timestamps through deterministic backplane communication cycles. In multi-chassis systems, time alignment is maintained through external reference inputs (GPS or NTP/PTP), while internal logic aligns module-level scheduling to controller scan cycles.

The module integrates into the 1756 platform communication layer, where backplane timing is exchanged alongside cyclic I/O updates and controller task execution windows.

In systems utilizing EtherNet/IP, external time synchronization can be aligned with PTP boundary clock behavior, allowing coordinated timestamping between distributed controllers and remote I/O nodes.

Frequently Asked Questions (FAQ)

Q: Does the 1756HP-TIME/B support hot-swap replacement in a powered ControlLogix chassis?
A: The module follows standard ControlLogix hot-swap rules. Replacement behavior depends on chassis configuration and controller scan state.

Q: How does the module prioritize NTP versus IEEE 1588 PTP time sources?
A: Source selection is governed by system configuration and synchronization hierarchy defined in the ControlLogix time service settings.

Q: Can multiple 1756HP-TIME/B modules operate in the same backplane?
A: Only one primary time authority configuration is typically active per chassis scope, while additional modules may remain in standby depending on system design.


Field Installation Guidelines

Install the module only in a compatible ControlLogix 1756 chassis slot with proper backplane seating. Ensure full insertion into the backplane connector to maintain deterministic timing communication.

For GPS-based synchronization, route antenna cabling away from high-noise power conductors and variable frequency drive outputs. Maintain continuous shielding continuity and ground termination at a single reference point to reduce timing jitter induced by EMI coupling.

For NTP/PTP deployments, verify network segmentation and switch configuration support for time-sensitive traffic. Avoid unmanaged switching paths that may introduce variable latency into synchronization streams.

Do not install adjacent to high-thermal modules without observing chassis airflow distribution constraints defined by system-level installation standards.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products