{"product_id":"allen-bradley-1761-cbl-pm02-micrologix-programming-cable","title":"Allen-Bradley 1761-CBL-PM02 MicroLogix Programming Cable","description":"\u003ch2\u003eAllen-Bradley 1761-CBL-PM02 MicroLogix Programming Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for RS-232 communication connection in MicroLogix 1000 controller systems, the \u003cstrong\u003eAllen-Bradley 1761-CBL-PM02\u003c\/strong\u003e (\u003cstrong\u003e1761-CBL-PM02\u003c\/strong\u003e Programming Cable) provides direct physical\/electrical execution through an 8-pin Mini DIN to 9-pin D-Shell interface. The 2 meter cable assembly supports PC communication links and serial data transfer between controller hardware and programming terminals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1761-CBL-PM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgramming Cable \/ Network Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e8-Pin Mini DIN to 9-Pin D-Shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003eSupported with 9-pin D-Shell serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2 m cable assembly length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and MicroLogix Serial Communication Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1761-CBL-PM02 cable is configured for MicroLogix controller programming and communication connections through RS-232 serial signaling. The cable assembly provides the required pin conversion between the controller-side 8-pin Mini DIN interface and PC-side 9-pin D-Shell serial interface. Series C or later cable models support Class 1 Division 2 application requirements.\u003c\/p\u003e\n\u003cp\u003eThe cable is designed for physical data transmission only and does not contain active communication electronics, firmware, or protocol processing components. Installation requires correct connector orientation and separation from high-noise power conductors to maintain signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1761-CBL-PM02 cable require an external power supply?\u003cbr\u003eA: No. The cable is a passive RS-232 communication assembly and receives no external operating power.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interface is supported by the 1761-CBL-PM02?\u003cbr\u003eA: The cable supports RS-232 connections using an 8-pin Mini DIN connector on the controller side and a 9-pin D-Shell connector for PC communication.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable be installed in Class 1 Division 2 applications?\u003cbr\u003eA: Class 1 Division 2 application support applies to Series C or later cable models according to the specified product requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the cable with the connectors fully seated and secured to prevent intermittent serial communication faults. Route the communication cable separately from high-voltage power wiring, motor leads, and sources of electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable shielding practices where applicable, with shield termination following the controller panel grounding design. Avoid sharp bends, excessive mechanical stress, and cable routing paths that may expose the assembly to abrasion or chemical damage.\u003c\/p\u003e\n\u003cp\u003eVerify connector pin compatibility before connecting the cable between MicroLogix controllers and PC programming equipment. Confirm environmental conditions remain within the specified operating temperature and humidity limits.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43649952677978,"sku":"1761-CBL-PM02","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1761-CBL-PM022.jpg?v=1783927197","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1761-cbl-pm02-micrologix-programming-cable","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}