{"product_id":"allen-bradley-1761-net-aic-micrologix-advanced-interface-converter","title":"Allen-Bradley 1761-NET-AIC MicroLogix Advanced Interface Converter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-AIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an AIC+ Advanced Interface Converter designed for the Allen-Bradley MicroLogix communication ecosystem. It is used to bridge and isolate serial communication networks, enabling reliable data exchange across DH-485 and DF1 protocols in multidrop configurations.\u003c\/p\u003e\n\u003cp\u003eThis device supports up to 32 nodes on a DH-485 network, making it suitable for small to medium distributed control systems. It provides electrical isolation between communication channels, improving signal integrity and protecting connected controllers from electrical noise and ground loops.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-AIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates from a 24V DC power supply and integrates multiple serial interfaces for flexible network connectivity, including RS-232 and DH-485 communication paths. Its compact design allows easy installation in industrial enclosures with DIN rail mounting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol Support: DH-485, DF1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePorts:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × RS-232 serial ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × DH-485 port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMultidrop Network Support: Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Nodes: up to 32 DH-485 devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: 20.4–28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical Current Draw: up to 120 mA @ 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Inrush Current: 200 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal Isolation: 500V DC tested (60 seconds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance \u0026amp; Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Isolation: RS-232 to RS-485 conversion isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNoise Immunity: enhanced industrial-grade filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Stability: optimized for multidrop serial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5%–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Resistance: 5 g (10–500 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 30 g operating \/ 50 g non-operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Type: DIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.4 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact interface module design for cabinet integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications \u0026amp; Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUL Listed for Class I Division 2 hazardous locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Groups A, B, C, D environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSerial network bridging for MicroLogix systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multidrop DH-485 architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation between communication domains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual RS-232 interface for flexible connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMicroLogix PLC communication networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy DH-485 system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial device networking in control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit communication expansion projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many devices can be connected on a DH-485 network using this module?\u003c\/strong\u003e\u003cbr\u003eA: Up to 32 nodes are supported in a multidrop configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes 500V DC isolation to protect communication lines and connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used with DF1 communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports DF1 protocol alongside DH-485 for flexible serial communication.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43291874263130,"sku":"1761-NET-AIC","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1761-NET-AIC2.jpg?v=1777530788","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1761-net-aic-micrologix-advanced-interface-converter","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}