{"id":43655879262298,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1763-NC01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1763-NC01 MicroLogix 1100 Communication Cable","public_title":null,"options":["Default Title"],"price":12300,"weight":50,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1763-NC01 MicroLogix 1100 Communication Cable

The Allen-Bradley 1763-NC01, also cataloged as the 1763-NC01 MicroLogix 1100 Communication Cable, operates as a dedicated hardware component for RS-485 serial connection between MicroLogix 1100 controllers and DH-485 network interfaces. The cable provides an 8-pin Mini-DIN controller connection and a 6-pin terminal block interface for PLC communication and programming functions.

Hardware Specifications

Parameter Specification
Model 1763-NC01
Brand Allen-Bradley
Origin USA
Weight 0.11 lbs
Power Consumption Passive cable assembly, no external power consumption
Product Type Communication Cable
Controller Compatibility MicroLogix 1100 controllers (Bulletin 1763)
Communication Interface RS-485 serial communication / DH-485 network
Connector Type 8-pin Mini-DIN to 6-pin terminal block
Isolation Isolated RS-232/RS-485 combination port support
Application PLC programming, monitoring, and network communication
Hazardous Location Use Class I Division 2 applications
Programming Software Compatibility RSLogix 500

EtherNet/IP and Industrial Communication Interface Compatibility

The 1763-NC01 cable provides physical signal routing between the MicroLogix 1100 Channel 0 communication port and RS-485 network wiring. The 8-pin Mini-DIN connector interfaces with the controller serial port, while the 6-pin terminal block provides field wiring access for DH-485 communication networks. The cable assembly is designed for short-distance panel connections where direct serial communication access is required.

The cable supports isolated serial communication configurations used with MicroLogix 1100 controllers. Proper shield termination and cable routing practices are required to maintain signal integrity in industrial control panels with electrical noise sources.

Frequently Asked Questions

Q: What controller family is compatible with the Allen-Bradley 1763-NC01 cable?
A: The 1763-NC01 is designed for Allen-Bradley MicroLogix 1100 controllers (Bulletin 1763) and provides connection from the Channel 0 port to DH-485 RS-485 networks.

Q: Does the 1763-NC01 cable require an external power supply?
A: No. The cable is a passive communication accessory and does not require external power.

Q: What are the connector interfaces provided by this cable?
A: The cable uses an 8-pin Mini-DIN connector on the controller side and a 6-pin terminal block connection on the RS-485 network side.

Field Installation Guidelines

Install the 1763-NC01 cable directly between the MicroLogix 1100 Channel 0 communication port and the designated RS-485/DH-485 terminal connection. Verify connector orientation before insertion to prevent mechanical damage to communication ports.

Route the cable separately from high-voltage power conductors, motor cables, and high-current switching circuits to reduce electromagnetic interference. Connect cable shields according to the controller and network grounding requirements. Maintain proper terminal block wiring polarity for RS-485 differential communication signals.

Avoid excessive mechanical stress on the Mini-DIN connector and maintain secure cable routing inside the control enclosure. Confirm communication parameters and network addressing before commissioning the PLC communication link.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products