{"product_id":"allen-bradley-1763-nc01-micrologix-1100-communication-cable","title":"Allen-Bradley 1763-NC01 MicroLogix 1100 Communication Cable","description":"\u003ch2\u003eAllen-Bradley 1763-NC01 MicroLogix 1100 Communication Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1763-NC01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1763-NC01\u003c\/strong\u003e MicroLogix 1100 Communication Cable, operates as a dedicated hardware component for RS-485 serial connection between MicroLogix 1100 controllers and DH-485 network interfaces. The cable provides an 8-pin Mini-DIN controller connection and a 6-pin terminal block interface for PLC communication and programming functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1763-NC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly, no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1100 controllers (Bulletin 1763)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 serial communication \/ DH-485 network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e8-pin Mini-DIN to 6-pin terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIsolated RS-232\/RS-485 combination port support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePLC programming, monitoring, and network communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Use\u003c\/td\u003e\n\u003ctd\u003eClass I Division 2 applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software Compatibility\u003c\/td\u003e\n\u003ctd\u003eRSLogix 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Industrial Communication Interface Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1763-NC01 cable provides physical signal routing between the MicroLogix 1100 Channel 0 communication port and RS-485 network wiring. The 8-pin Mini-DIN connector interfaces with the controller serial port, while the 6-pin terminal block provides field wiring access for DH-485 communication networks. The cable assembly is designed for short-distance panel connections where direct serial communication access is required.\u003c\/p\u003e\n\u003cp\u003eThe cable supports isolated serial communication configurations used with MicroLogix 1100 controllers. Proper shield termination and cable routing practices are required to maintain signal integrity in industrial control panels with electrical noise sources.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What controller family is compatible with the Allen-Bradley 1763-NC01 cable?\u003cbr\u003eA: The 1763-NC01 is designed for Allen-Bradley MicroLogix 1100 controllers (Bulletin 1763) and provides connection from the Channel 0 port to DH-485 RS-485 networks.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 1763-NC01 cable require an external power supply?\u003cbr\u003eA: No. The cable is a passive communication accessory and does not require external power.\u003c\/p\u003e\n\u003cp\u003eQ: What are the connector interfaces provided by this cable?\u003cbr\u003eA: The cable uses an 8-pin Mini-DIN connector on the controller side and a 6-pin terminal block connection on the RS-485 network side.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1763-NC01 cable directly between the MicroLogix 1100 Channel 0 communication port and the designated RS-485\/DH-485 terminal connection. Verify connector orientation before insertion to prevent mechanical damage to communication ports.\u003c\/p\u003e\n\u003cp\u003eRoute the cable separately from high-voltage power conductors, motor cables, and high-current switching circuits to reduce electromagnetic interference. Connect cable shields according to the controller and network grounding requirements. Maintain proper terminal block wiring polarity for RS-485 differential communication signals.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive mechanical stress on the Mini-DIN connector and maintain secure cable routing inside the control enclosure. Confirm communication parameters and network addressing before commissioning the PLC communication link.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43655879262298,"sku":"1763-NC01","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1763-NC012.jpg?v=1784008835","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1763-nc01-micrologix-1100-communication-cable","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}