Skip to content
Allen-Bradley 1785-L80B PLC-5/80 Processor Module

Allen-Bradley 1785-L80B PLC-5/80 Processor Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1785-L80B

  • Condition: In stock

  • Product Type: PLC-5/80 Processor Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1361g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43739355676762,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1785-L80B","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1785-L80B PLC-5\/80 Processor Module","public_title":null,"options":["Default Title"],"price":12300,"weight":1361,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1785-L80B PLC-5/80 Processor Module

The Allen-Bradley 1785-L80B serves as the primary 1785-L80B PLC-5/80 Processor Module utilized to execute programmable control processing and high-density I/O communication tasks across PLC-5 DH+ / Remote I/O platforms. The processor provides 100 Kilowords of battery-backed SRAM, multi-channel communication interfaces, and PLC-5 chassis management functions.

Hardware Specifications

Parameter Specification
Model 1785-L80B
Brand Allen-Bradley
Origin United States
Weight 3.00 lbs
Power Consumption 12 W power dissipation; 2.3 A backplane current draw
Module Type PLC-5/80 Processor Module
Product Line PLC-5
Processor PLC-5/80
User Memory 100 Kilowords battery-backed static RAM
Memory Expansion Supports 1785-ME16, 1785-ME32, and 1785-ME64 modules
EEPROM Program Backup Supported using 1785-ME16, 1785-ME32, 1785-ME64, and 1785-M100 modules
Protected Memory No
Maximum Total I/O 3072 points any mix or 3072 inputs + 3072 outputs complementary
Maximum Analog I/O 3072
Maximum I/O Chassis Total 93
Maximum I/O Racks 32
Universal Remote I/O Chassis 32 maximum per I/O link
Communication Ports 4 x DH+/Remote I/O (Adapter or Scanner), 1 x serial port, 2 x programming terminals
Serial Port Compatibility RS-232, RS-422A, RS-423
Supported Protocols DF1, ASCII, Data Highway Plus (DH+), Remote I/O (RIO)
Controller Redundancy Supported
Battery Type 1770-XYC
Control Coprocessor Expansion Port Supported
I/O Scan Time Per Rack 10 ms at 57.6 kbits/s, 7 ms at 115.2 kbits/s, 3 ms at 230.4 kbits/s

I/O Density Scaling and PLC-5 Communication Architecture

The 1785-L80B processor provides PLC-5 architecture functions for deterministic control execution through DH+ and Remote I/O communication channels. The processor supports I/O density scaling with up to 3072 I/O points and distributed rack configurations using universal Remote I/O links.

The processor manages multiple communication paths through four DH+/Remote I/O channels configured for adapter or scanner operation. The PLC-5 platform supports firmware-compatible memory expansion and EEPROM backup functions for program transfer and retention. Controller redundancy capability allows coordinated processor configurations where supported by the system design.

Frequently Asked Questions

Q: What is the maximum user memory capacity of the 1785-L80B processor?
A: The processor provides up to 100 Kilowords of battery-backed static RAM user memory.

Q: How many communication channels are integrated into the 1785-L80B?
A: The processor includes four DH+/Remote I/O channels, one configurable serial port supporting RS-232, RS-422A, and RS-423, and two programming terminal connections.

Q: Does the 1785-L80B support PLC-5 redundancy configurations?
A: Yes. Controller redundancy support is provided for compatible PLC-5 system architectures.

Field Installation Guidelines

Install the 1785-L80B processor module in the designated PLC-5 chassis slot with chassis power removed during installation or removal. Verify that the rack configuration, processor addressing, and memory modules match the application requirements.

Route DH+, Remote I/O, and serial communication cables separately from power conductors and high-current switching circuits. Use appropriate cable shielding and grounding methods according to industrial control wiring practices.

Before operation, verify processor status indicators, battery condition, communication configuration, I/O rack addressing, and application memory integrity. Confirm that all connected 1771 I/O modules correspond with the configured PLC-5 program structure.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.