{"id":43762691342426,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1788-CNCHKR","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen Bradley 1788-CNCHKR ControlNet NetChecker","public_title":null,"options":["Default Title"],"price":12300,"weight":340,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen Bradley 1788-CNCHKR ControlNet NetChecker

The Allen Bradley 1788-CNCHKR, also cataloged as the 1788-CNCHKR ControlNet NetChecker, operates as a dedicated hardware component for active ControlNet coaxial network diagnostics within ControlNet network platforms. The hand-held diagnostic tool provides node address selection, LED status indication, and signal monitoring functions.

Suffix Breakdown & Model Matrix

The available technical documentation identifies 1788-CNCHKR as a fixed catalog number within the Allen Bradley 1788 Linking Devices product line. No additional suffix breakdown or configurable ordering matrix is specified.

Hardware Specifications

Parameter Specification
Model 1788-CNCHKR
Brand Allen Bradley
Product Type ControlNet NetChecker
Product Line 1788 Linking Devices
Weight 0.75 lbs
Power Consumption Battery powered, 6 hours battery life
Required Batteries 2 x 1.5 VDC AA batteries
Network Interface ControlNet coaxial signal
BNC Connector 1 x BNC
Display 8 bi-color Red/Green status indicators
Status Indicators Diagnostic or Bargraph modes
Buzzer Piezo audible fault indication
DC Input External DC power jack
Oscilloscope Connector 3-pin Phoenix connector
Node Address Range 0 to 99
Function Switch 4-position diagnostic/bargraph selection
Power Switch 3-position OFF/ON/Push ON

Profinet / EtherNet-IP Deterministic Network Integration

The 1788-CNCHKR is a portable ControlNet diagnostic instrument designed for physical layer network verification. The tool monitors active ControlNet coaxial communication conditions through a BNC interface and provides visual diagnostic feedback through dual-color status indicators.

Allen Bradley industrial network diagnostics rely on communication integrity analysis, network node identification, and field troubleshooting procedures. The device supports node address entry through two-digit decimal thumbwheel switches and provides diagnostic threshold selection through the function switch.

Frequently Asked Questions

Q: Does the 1788-CNCHKR provide permanent external power operation?
A: The device supports external DC power through the DC jack. Normal operation is also supported by two 1.5 VDC AA batteries.

Q: What type of connector is used for oscilloscope monitoring?
A: The module provides a 3-pin Phoenix connector for oscilloscope connection.

Q: How is the ControlNet node selected for diagnostic testing?
A: The target node address is entered using two-digit decimal thumbwheel switches with an address range from 0 to 99.


Field Installation Guidelines

  • Connect the BNC interface directly to the ControlNet coaxial segment under test according to the network access procedure.

  • Verify the selected node address before starting diagnostic measurements.

  • Keep diagnostic connections physically separated from high-voltage wiring and high-noise power conductors.

  • Use the provided oscilloscope connector only with compatible measurement equipment.

  • Confirm battery condition before field deployment and use the external DC jack when required.

  • Observe cable shielding and grounding practices during ControlNet coaxial signal inspection.

  • Do not modify internal wiring or switch configurations beyond the specified diagnostic functions.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products