Skip to content
Allen-Bradley 1791DS-IB8XOB8 Guard I/O Safety I/O Module

Allen-Bradley 1791DS-IB8XOB8 Guard I/O Safety I/O Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1791DS-IB8XOB8

  • Condition: In stock

  • Product Type: Guard I/O Safety I/O Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 422g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43763016728666,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1791DS-IB8XOB8","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1791DS-IB8XOB8 Guard I\/O Safety I\/O Module","public_title":null,"options":["Default Title"],"price":12300,"weight":422,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1791DS-IB8XOB8 Guard I/O Safety I/O Module

Configured for safety signal acquisition and output switching in Guard I/O 1791ES and 1791DS DeviceNet platforms, the Allen-Bradley 1791DS-IB8XOB8 (1791DS-IB8XOB8 Safety I/O Module) provides direct physical/electrical execution through eight sinking safety inputs and eight sourcing safety outputs.

Hardware Specifications

Parameter Specification
Model 1791DS-IB8XOB8
Brand Allen-Bradley
Origin United States
Weight 0.93 lbs
Operating Temp -40 to 70 deg C (-40 to 158 deg F)
Power Consumption 110 mA @ 24 VDC
Product Line Guard I/O 1791ES and 1791DS
Module Type Guard I/O DeviceNet Safety I/O Module
Communication Interface DeviceNet
Safety Inputs 8 sinking inputs
Safety Outputs 8 sourcing outputs
Test Outputs 4 sourcing outputs
Input Type Single-channel
Output Type Current sourcing
Operating Voltage Range 20.4-26.4 VDC
Communications Power Supply 11-25 VDC
Communications Current Consumption 110 mA at 24 VDC
On-State Input Voltage 11 VDC minimum
Off-State Input Voltage 5 VDC maximum
Rated Output Current 0.7 A
Enclosure Rating IP20
Mounting Type DIN rail mount
Wire Specification Copper 0.2-2.5 mm2 (AWG 24-12) solid wire, 0.34-1.5 mm2 (AWG 22-16) flexible wire

EtherNet/IP and DeviceNet Safety Architecture

The 1791DS-IB8XOB8 operates as a CompactBlock Guard I/O DeviceNet safety module with integrated input and output processing. The module supports I/O density scaling by combining safety input monitoring and solid-state safety output control in a single field-mounted block.

Allen-Bradley Guard I/O modules require compatible safety controllers and configured DeviceNet safety communication parameters. Firmware flash compatibility and network configuration must be verified before integration into an existing safety control architecture.

The module provides current sinking input channels, current sourcing safety outputs, and dedicated test outputs for safety device diagnostics. Output channels are designed for controlled DC switching with a rated output current of 0.7 A per safety output.

Frequently Asked Questions

Q: How many safety input and output channels are available on the 1791DS-IB8XOB8?
A: The module provides 8 sinking safety inputs and 8 sourcing safety outputs, with 4 additional sourcing test outputs.

Q: What DC supply range is required for I/O operation?
A: The I/O power supply operates within 20.4-26.4 VDC, based on a 24 VDC nominal supply.

Q: Does the module support SIL3 safety applications?
A: The module is specified as a Guard I/O DeviceNet Safety module suitable for applications requiring SIL3-level safety requirements when applied within an approved safety system configuration.

Field Installation Guidelines

Install the 1791DS-IB8XOB8 on a compatible DIN rail structure and verify mechanical retention before wiring field devices. Confirm that power supply polarity, DeviceNet communication connections, and safety I/O terminal assignments match the system design documentation.

Use appropriate cable routing practices to separate safety signal wiring from high-voltage power conductors and sources of electrical interference. Cable shielding and grounding methods should follow the control panel and safety system installation standards.

Before commissioning, verify each safety input transition, safety output response, and test output diagnostic function. Confirm DeviceNet node configuration, safety communication status, and field device wiring integrity before placing the module into operational service.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products