Skip to content
Allen-Bradley 1794-IB10XOB6XT FLEX I/O XT Combination Digital I/O Module

Allen-Bradley 1794-IB10XOB6XT FLEX I/O XT Combination Digital I/O Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-IB10XOB6XT

  • Condition: In stock

  • Product Type: FLEX I/O XT Combination Digital I/O Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43768152129626,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1794-IB10XOB6XT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1794-IB10XOB6XT FLEX I\/O XT Combination Digital I\/O Module","public_title":null,"options":["Default Title"],"price":12300,"weight":300,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1794-IB10XOB6XT FLEX I/O XT Combination Digital I/O Module

The Allen-Bradley 1794-IB10XOB6XT, also cataloged as the 1794-IB10XOB6XT Combination Digital I/O Module, operates as a dedicated hardware component for 24 VDC field signal acquisition and output execution within the FLEX I/O XT system network. The module integrates 10 current-sinking digital inputs and 6 sourcing digital outputs for distributed industrial control applications.

Hardware Specifications

Parameter Specification
Model 1794-IB10XOB6XT
Brand Allen-Bradley / Rockwell Automation
Origin Not specified in supplied data
Product Line FLEX I/O XT
Module Type Combination Digital Input/Output Module
Number of Inputs 10 sinking digital inputs
Number of Outputs 6 sourcing digital outputs
Nominal Voltage 24 VDC
Operating Voltage Range 10 VDC to 31.2 VDC
Input On-State Voltage 10 VDC min. to 31.2 VDC max.
Input Off-State Voltage 5 VDC max.
Input On-State Current 2.0 mA min. at 10 VDC; 11.0 mA max. at 31.2 VDC
Output Current Range 10 mA min. to 0.5 A max. per channel
Maximum Total Output Current 3.0 A per module
FlexBus Current 80 mA at 5 VDC
Power Consumption Max. 4.5 W at 31.2 VDC
Thermal Dissipation Max. 15.3 BTU/hr at 31.2 VDC
Isolation Voltage 50 V continuous, Basic Insulation Type
Operating Temp -20 deg C to +70 deg C
Storage Temp -40 deg C to +85 deg C
Relative Humidity 5% to 95%, non-condensing

EtherNet/IP Deterministic Networks and FLEX I/O XT Architecture

The 1794-IB10XOB6XT operates within the FLEX I/O XT modular architecture through a 1794 terminal base assembly. The module provides combined digital input sensing and transistor output switching in a single I/O position, reducing the number of separate field interface modules required. The XT design includes conformal coating protection for circuit assemblies exposed to humidity, corrosive gases, airborne dust, and industrial contaminants.

The module supports distributed I/O expansion through FLEXBus communication and provides front-panel LED indicators for individual channel status monitoring. The terminal base design allows terminal replacement without removal of connected field wiring.

Frequently Asked Questions (FAQ)

Q: Can the 1794-IB10XOB6XT be installed or removed under power?
A: Hot-swap capability depends on the installed FLEX I/O system configuration and controller requirements. Follow the applicable Rockwell Automation installation manual before performing module replacement under power.

Q: What is the maximum output load capability of the module?
A: Each sourcing output channel supports up to 0.5 A, with a maximum total output current of 3.0 A per module.

Q: Is firmware flash compatibility required for this module?
A: Firmware compatibility must be verified with the installed FLEX I/O adapter, controller platform, and system revision before firmware updates are performed.

Field Installation Guidelines

  • Install the module on the specified 1794 terminal base unit and verify mechanical engagement before applying field power.
  • Separate digital signal wiring from high-current power conductors to reduce electrical interference.
  • Connect cable shields according to the control system grounding practice and applicable site standards.
  • Verify input polarity and output load wiring before energizing the module.
  • Confirm that the installation environment remains within the specified operating temperature and humidity limits.
  • Use appropriate enclosure protection when the module is installed in areas containing dust, moisture, or corrosive airborne contaminants.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products