{"product_id":"allen-bradley-1794-ib10xob6xt-flex-i-o-xt-combination-digital-i-o-module","title":"Allen-Bradley 1794-IB10XOB6XT FLEX I\/O XT Combination Digital I\/O Module","description":"\u003ch2\u003eAllen-Bradley 1794-IB10XOB6XT FLEX I\/O XT Combination Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-IB10XOB6XT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-IB10XOB6XT\u003c\/strong\u003e Combination Digital I\/O Module, operates as a dedicated hardware component for 24 VDC field signal acquisition and output execution within the FLEX I\/O XT system network. The module integrates 10 current-sinking digital inputs and 6 sourcing digital outputs for distributed industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IB10XOB6XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCombination Digital Input\/Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e10 sinking digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6 sourcing digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 VDC to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e10 VDC min. to 31.2 VDC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Off-State Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput On-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0 mA min. at 10 VDC; 11.0 mA max. at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e10 mA min. to 0.5 A max. per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Total Output Current\u003c\/td\u003e\n\u003ctd\u003e3.0 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexBus Current\u003c\/td\u003e\n\u003ctd\u003e80 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 4.5 W at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003eMax. 15.3 BTU\/hr at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous, Basic Insulation Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Networks and FLEX I\/O XT Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1794-IB10XOB6XT operates within the FLEX I\/O XT modular architecture through a 1794 terminal base assembly. The module provides combined digital input sensing and transistor output switching in a single I\/O position, reducing the number of separate field interface modules required. The XT design includes conformal coating protection for circuit assemblies exposed to humidity, corrosive gases, airborne dust, and industrial contaminants.\u003c\/p\u003e\n\u003cp\u003eThe module supports distributed I\/O expansion through FLEXBus communication and provides front-panel LED indicators for individual channel status monitoring. The terminal base design allows terminal replacement without removal of connected field wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1794-IB10XOB6XT be installed or removed under power?\u003cbr\u003eA: Hot-swap capability depends on the installed FLEX I\/O system configuration and controller requirements. Follow the applicable Rockwell Automation installation manual before performing module replacement under power.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum output load capability of the module?\u003cbr\u003eA: Each sourcing output channel supports up to 0.5 A, with a maximum total output current of 3.0 A per module.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware flash compatibility required for this module?\u003cbr\u003eA: Firmware compatibility must be verified with the installed FLEX I\/O adapter, controller platform, and system revision before firmware updates are performed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on the specified 1794 terminal base unit and verify mechanical engagement before applying field power.\u003c\/li\u003e\n\u003cli\u003eSeparate digital signal wiring from high-current power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the control system grounding practice and applicable site standards.\u003c\/li\u003e\n\u003cli\u003eVerify input polarity and output load wiring before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installation environment remains within the specified operating temperature and humidity limits.\u003c\/li\u003e\n\u003cli\u003eUse appropriate enclosure protection when the module is installed in areas containing dust, moisture, or corrosive airborne contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43768152129626,"sku":"1794-IB10XOB6XT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IB10XOB6XT2.jpg?v=1785481568","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1794-ib10xob6xt-flex-i-o-xt-combination-digital-i-o-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}