{"product_id":"allen-bradley-1794-ib16xt-flex-i-o-digital-input-module","title":"Allen-Bradley 1794-IB16XT FLEX I\/O Digital Input Module","description":"\u003ch2\u003eAllen-Bradley 1794-IB16XT FLEX I\/O Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-IB16XT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-IB16XT\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for 24 VDC discrete signal acquisition within FLEX I\/O system platforms. It provides 16 input channels with sinking\/sourcing capability and extended temperature operation for industrial control installations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IB16XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O Extended Temperature (XT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Sinking \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 points, 1 group of 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.0 VDC to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e10.0 VDC to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0 mA minimum at 10 VDC, 4.1 mA typical at 24 VDC, 8.0 mA maximum at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e1.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexBus Current\u003c\/td\u003e\n\u003ctd\u003e30 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.1 W maximum at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e20.8 BTU\/hr maximum at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V continuous, Basic Insulation Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5 g at 10 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 yellow input status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eOpen style, DIN mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and FLEX I\/O Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1794-IB16XT interfaces with FLEX I\/O architecture through the FlexBus connection for distributed I\/O communication. The module provides 16 discrete input points with channel status indication through individual LED diagnostics. Configuration and data exchange depend on the connected FLEX I\/O adapter and controller platform. The XT design supports operation across an extended temperature range without changing the standard FLEX I\/O module form factor.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal types are supported by the 1794-IB16XT module?\u003cbr\u003eA: The module supports 24 VDC digital input signals with current sinking and sourcing operation across 16 input points.\u003c\/p\u003e\n\u003cp\u003eQ: What is the FlexBus current requirement of the module?\u003cbr\u003eA: The module requires 30 mA at 5 VDC from the FlexBus supply.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide individual input diagnostics?\u003cbr\u003eA: Yes. The module includes 16 yellow status LEDs, with one indicator assigned to each input point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module on a DIN mounting system with the required FLEX I\/O adapter and terminal base assembly. Maintain separation between discrete input wiring and high-voltage or high-noise conductors to reduce signal interference. Connect cable shields according to the control panel grounding design and avoid creating unintended ground loops.\u003c\/p\u003e\n\u003cp\u003eVerify that field devices provide voltage levels within the specified input operating range before connection. Confirm terminal wiring polarity for sinking or sourcing input configurations. Installation should consider enclosure ventilation, environmental protection, and accessibility for module status indication and maintenance inspection.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43768284414042,"sku":"1794-IB16XT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IB16XT2.jpg?v=1785483064","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1794-ib16xt-flex-i-o-digital-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}