{"product_id":"allen-bradley-1794-ie8xt-flex-i-o-analog-input-module","title":"Allen Bradley 1794-IE8XT Flex I\/O Analog Input Module","description":"\u003ch2\u003eAllen Bradley 1794-IE8XT Flex I\/O Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition in the Allen Bradley Flex I\/O 1794 system, the \u003cstrong\u003eAllen Bradley 1794-IE8XT\u003c\/strong\u003e (\u003cstrong\u003e1794-IE8XT\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution for eight single-ended current or voltage input channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IE8XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFlex I\/O 1794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 single-ended inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent or voltage analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eSuccessive approximation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Current\u003c\/td\u003e\n\u003ctd\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C extended temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.88 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 open style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1794-IE8XT operates as a Flex I\/O analog acquisition module with eight input channels connected through the FlexBus communication interface. The module processes field analog signals using successive approximation conversion and transfers channel data through the distributed I\/O architecture. I\/O density scaling is achieved through the Flex I\/O modular structure, allowing multiple signal modules to be installed within a common remote I\/O assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What type of input signals does the 1794-IE8XT process?\u003cbr\u003eA: The module processes eight single-ended analog inputs configured for current or voltage measurement applications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the FlexBus current requirement of the 1794-IE8XT?\u003cbr\u003eA: The module requires 60 mA from the FlexBus interface for operation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1794-IE8XT be installed in extended temperature environments?\u003cbr\u003eA: The module is specified for extended temperature operation from -20 to 70 deg C according to the provided technical data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1794-IE8XT on a compatible DIN rail mounting assembly within the Flex I\/O system configuration. Verify that field wiring is separated from high voltage conductors and routed according to industrial control cabinet practices.\u003c\/p\u003e\n\u003cp\u003eUse shielded cable where required by the analog signal environment. Connect cable shields according to the control system grounding design to reduce electrical interference. Confirm correct polarity and channel assignment before energizing the external 24 VDC supply.\u003c\/p\u003e\n\u003cp\u003eMaintain adequate cabinet ventilation and verify that environmental conditions remain within the specified operating range. Check FlexBus connections for proper mechanical engagement before commissioning the module.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43778306605146,"sku":"1794-IE8XT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IE8XT2.jpg?v=1785741027","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1794-ie8xt-flex-i-o-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}