{"product_id":"allen-bradley-1794-if2xof2i-flex-i-o-isolated-analog-i-o-module","title":"Allen Bradley 1794-IF2XOF2I Flex I\/O Isolated Analog I\/O Module","description":"\u003ch2\u003eAllen Bradley 1794-IF2XOF2I Flex I\/O Isolated Analog I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 1794-IF2XOF2I\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-IF2XOF2I\u003c\/strong\u003e Flex I\/O Isolated Analog I\/O Module, operates as a dedicated hardware component for isolated analog signal acquisition and output execution within the Allen Bradley Flex I\/O 1794 system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IF2XOF2I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlex I\/O Isolated Input\/Output Analog Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFlex I\/O 1794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e2 isolated analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eSigma Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Terminal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Terminal\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Terminal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Terminal\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexBus Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eThermal dissipation 11.3 BTU\/hr at 31.2 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabeling\u003c\/td\u003e\n\u003ctd\u003eRemovable identification label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1794-IF2XOF2I integrates isolated analog input and output channels within the Flex I\/O 1794 distributed I\/O architecture. The module performs analog-to-digital and digital-to-analog conversion using sigma delta conversion technology. I\/O density scaling is achieved through the modular FlexBus structure, allowing combined analog signal processing and remote I\/O expansion within a common platform.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog channels are available on the 1794-IF2XOF2I?\u003cbr\u003eA: The module provides two isolated analog inputs and two isolated analog outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What conversion method is used by the analog input section?\u003cbr\u003eA: The analog input section uses sigma delta conversion with 16-bit resolution.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide channel isolation?\u003cbr\u003eA: Yes. The input and output channels are specified as isolated analog channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1794-IF2XOF2I on a compatible DIN rail assembly within the Flex I\/O 1794 system. Confirm correct module seating and FlexBus connection before applying field power.\u003c\/p\u003e\n\u003cp\u003eRoute analog signal wiring separately from high voltage and switching conductors. Use shielded instrumentation cable where required by the installation environment and terminate shields according to the control cabinet grounding design.\u003c\/p\u003e\n\u003cp\u003eVerify input and output terminal assignments before commissioning. Confirm the external 24 VDC supply wiring polarity and ensure the module remains within the specified environmental conditions provided by the system design.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43778312372314,"sku":"1794-IF2XOF21","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IF2XOF212.jpg?v=1785741352","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1794-if2xof2i-flex-i-o-isolated-analog-i-o-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}