{"product_id":"allen-bradley-1794-if4ixt-flex-i-o-analog-input-module","title":"Allen-Bradley 1794-IF4IXT Flex I\/O Analog Input Module","description":"\u003ch2\u003eAllen-Bradley 1794-IF4IXT Flex I\/O Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated analog signal acquisition in the Flex I\/O 1794 system, the \u003cstrong\u003eAllen-Bradley 1794-IF4IXT\u003c\/strong\u003e (\u003cstrong\u003e1794-IF4IXT\u003c\/strong\u003e Flex XT Analog Input Module) provides direct physical\/electrical execution for 4 channel industrial current and voltage input measurement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IF4IXT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlex XT 4 Point Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFlex I\/O 1794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eSigma Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Terminal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Terminal\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexBus Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W maximum at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.8 BTU\/hr at 31.2 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e55 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyswitch Position\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1794-IF4IXT operates as part of the Flex I\/O 1794 platform architecture, where distributed I\/O modules exchange process data through the FlexBus communication interface. The module supports isolated input channel configuration to separate field analog signals and reduce interference between measurement paths.\u003c\/p\u003e\n\u003cp\u003eThe isolated 4 point input design supports I\/O density scaling within Flex I\/O assemblies while maintaining independent signal conversion through Sigma Delta processing. Installation design should consider FlexBus loading, module addressing, and system communication timing requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1794-IF4IXT provide channel isolation for analog inputs?\u003cbr\u003eA: Yes. The module provides 4 isolated analog input channels with 120 V continuous isolation voltage rating.\u003c\/p\u003e\n\u003cp\u003eQ: What analog signal types are supported by the input terminals?\u003cbr\u003eA: The module supports 4-20 mA current inputs and +\/- 10 V voltage inputs.\u003c\/p\u003e\n\u003cp\u003eQ: What are the power and backplane current requirements?\u003cbr\u003eA: The module requires a 24 VDC nominal external supply and has a FlexBus current requirement of 50 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 1794-IF4IXT in a compatible Flex I\/O 1794 terminal base assembly according to the system hardware configuration.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation wiring for analog field signals where required by the installation environment. Connect cable shields according to the site grounding standard and avoid routing analog input wiring parallel to high current conductors or switching power lines.\u003c\/p\u003e\n\u003cp\u003eVerify terminal wiring polarity before energizing the module. Confirm the external 24 VDC supply quality and ensure the module is correctly seated in the terminal base to maintain FlexBus communication continuity.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between signal wiring and power distribution wiring to reduce electrical noise coupling into analog measurement channels.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43778313519194,"sku":"1794-IF4IXT","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1794-IF4IXT2.jpg?v=1785741792","url":"https:\/\/www.plcmasters.com\/products\/allen-bradley-1794-if4ixt-flex-i-o-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}