Skip to content
Allen-Bradley 1794-OE12/A FLEX I/O Analog Output Module

Allen-Bradley 1794-OE12/A FLEX I/O Analog Output Module

  • 16 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-OE12/A

  • Condition: In stock

  • Product Type: FLEX I/O Analog Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 100g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43782601113690,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1794-OE12\/A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Allen-Bradley 1794-OE12\/A FLEX I\/O Analog Output Module","public_title":null,"options":["Default Title"],"price":12300,"weight":100,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Allen-Bradley 1794-OE12/A FLEX I/O Analog Output Module

Configured for digital-to-analog signal execution in the FLEX I/O system, the Allen-Bradley 1794-OE12/A (1794-OE12 Analog Output Module) provides direct physical/electrical execution through 12 single-ended analog output channels.

Hardware Specifications

Parameter Specification
Model 1794-OE12/A
Brand Allen-Bradley / Rockwell Automation
Origin United States
Weight 100 g
Dimensions 46 x 94 x 53 mm
Operating Temp -20 deg C to +55 deg C
Power Consumption Max. 4.0 W at 31.2 VDC
Product Line FLEX I/O
Module Type High-Density Analog Output Module
Number of Outputs 12 single-ended analog outputs
Resolution 16-bit digital-to-analog conversion
Output Current Range 0 to 20 mA, 4 to 20 mA
Output Voltage Range +/-10 V, 0 to 10 V, +/-5 V, 0 to 5 V
Conversion Rate 1.0 ms for all channels
FlexBus Current 80 mA at 5 VDC
External Power Supply 24 VDC nominal (10.5 to 31.2 VDC)
External Current Consumption 280 mA at 24 VDC
Isolation Voltage 50 V continuous, tested at 850 VDC for 1 s (Output to FlexBus)
Terminal Base Units 1794-TB3G, 1794-TB3GS

EtherNet/IP and FLEX I/O Backplane Signal Processing

The 1794-OE12/A operates as a FLEX I/O analog output interface between controller data and field-level analog devices. The module receives digital values through the FLEX I/O communication bus and converts them into configured current or voltage output signals through individual DAC channels.

The Allen-Bradley FLEX I/O architecture supports modular I/O density scaling through terminal base installation. The 1794-OE12/A maintains channel-level configuration parameters and provides LED status indication for module power and operating diagnostics.

Firmware Flash Compatibility and I/O Configuration

The module configuration is controlled through the FLEX I/O system environment. Channel output ranges, signal types, and diagnostic states are defined through controller software configuration. Replacement modules require compatible hardware revision and configuration parameters to maintain existing application operation.

The 16-bit DAC architecture provides channel output control with current drive capability up to 750 ohm loads and voltage operation with minimum 2 kohm loads.

Frequently Asked Questions

Q: Can the 1794-OE12/A module be replaced without disconnecting field wiring?
A: The module supports hot-swappable replacement when installed on a compatible FLEX I/O terminal base. Field wiring remains connected through the terminal base assembly.

Q: What is the backplane current requirement of this analog output module?
A: The module requires 80 mA from the FLEX I/O 5 VDC backplane supply.

Q: Which analog output signals can be configured on the module?
A: The module supports configurable current outputs of 0 to 20 mA and 4 to 20 mA, and voltage outputs of +/-10 V, 0 to 10 V, +/-5 V, and 0 to 5 V.

Field Installation Guidelines

Install the 1794-OE12/A on a compatible FLEX I/O terminal base unit before connecting field conductors. Verify that the terminal base wiring matches the configured analog signal type before energizing the module.

Separate analog signal wiring from high-current power conductors and switching circuits to reduce electrical interference. Use shielded instrumentation cable where required by the installation design, and terminate cable shields according to the site grounding standard.

Confirm the external 24 VDC supply polarity and grounding arrangement before applying power. Check controller configuration, channel scaling, and output range settings before connecting field devices to the analog outputs.

Maintain proper cabinet spacing and environmental conditions within the specified operating temperature range. Ensure terminal connections are mechanically secured and protected from vibration exposure.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products